A22-MW-02A Omron, A22-MW-02A Datasheet
A22-MW-02A
Specifications of A22-MW-02A
Related parts for A22-MW-02A
A22-MW-02A Summary of contents
Page 1
... Available Colors Non-lighted: Red, green, yellow, white, blue, black Lighted: Red, green yellow, white, blue Lamp Light Source LED Lamp Incandescent Lamp Switch Unit Contacts SPST-NO, SPST-NC, SPST-NO + SPST-NC, DPST-NO, DPST-NC Lighting Method Non-lighted Lighted (without transformer) Lighted (with transformer) A22 ...
Page 2
... Illumination color (self-holding) A22-F -10A Insert one of the following letters into the A22-F -01A box box . A22-F -11A R (red) R (red) A22-F -20A Y (yellow) Y (yellow) G (green A22-F -02A W (white) W (white) A22-T -10A A (blue) A (blue) A22-T -01A B (black) B (black) A22-T -11A A22-T -20A ...
Page 3
... A22L-T -6D-10M 6 VAC A22L-T -6A-10M 12 VAC/DC A22L-T -12A-10M 24 VAC/DC A22L-T -24A-10M 6 VDC A22L-T -6D-01M 6 VAC A22L-T -6A-01M 12 VAC/DC A22L-T -12A-01M 24 VAC/DC A22L-T -24A-01M 6 VDC A22L-T -6D-11M 6 VAC A22L-T -6A-11M 12 VAC/DC A22L-T -12A-11M 24 VAC/DC A22L-T -24A-11M 6 VDC A22L-T -6D-20M 6 VAC A22L-T -6A-20M 12 VAC/DC ...
Page 4
... A22L-T -T1-11A G (green) G (green) A22L-T -T2-11A W (white) W (white) A22L-T -T1-20A A (blue) A (blue) A22L-T -T2-20A A22L-T -T1-02A A22L-T -T2-02A A22L-H -6D-10A A22L-H -6A-10A A22L-H -12A-10A A22L-H -24A-10A A22L-H -6D-01A A22L-H -6A-01A A22L-H -12A-01A A22L-H -24A-01A A22L-H -6D-11A A22L-H -6A-11A A22L-H -12A-11A A22L-H -24A-11A ...
Page 5
... A22L-H -T2-11A W (white) W (white) A22L-H -T1-20A A (blue) A (blue) A22L-H -T2-20A A22L-H -T1-02A A22L-H -T2-02A A22L-G -6D-10A A22L-G -6A-10A A22L-G -12A-10A A22L-G -24A-10A A22L-G -6D-01A A22L-G -6A-01A A22L-G -12A-01A A22L-G -24A-01A A22L-G -6D-11A A22L-G -6A-11A A22L-G -12A-11A A22L-G -24A-11A A22L-G -6D-20A A22L-G -6A-20A ...
Page 6
... A22L-C -6D-01A G (green) G (green) A22L-C -6A-01A W (white) W (white) A22L-C -12A-01A A (blue) A (blue) A22L-C -24A-01A A22L-C -6D-11A A22L-C -6A-11A A22L-C -12A-11A A22L-C -24A-11A A22L-C -6D-20A A22L-C -6A-20A A22L-C -12A-20A A22L-C -24A-20A A22L-C -6D-02A A22L-C -6A-02A A22L-C -12A-02A A22L-C -24A-02A A22L-C -T1-10A A22L-C -T2-10A ...
Page 7
... A22L-D -6D-01A G (green) G (green) A22L-D -6A-01A W (white) W (white) A22L-D -12A-01A A (blue) A (blue) A22L-D -24A-01A A22L-D -6D-11A A22L-D -6A-11A A22L-D -12A-11A A22L-D -24A-11A A22L-D -6D-20A A22L-D -6A-20A A22L-D -12A-20A A22L-D -24A-20A A22L-D -6D-02A A22L-D -6A-02A A22L-D -12A-02A A22L-D -24A-02A A22L-D -T1-10A A22L-D -T2-10A ...
Page 8
... Operational Unit Lighted (without transformer) Lighted Operational Unit (with transformer) 1. Operational Unit 1 Lighted/Non-lighted Code Description None Non-lighted L Lighted 8 Lamp LED Incandescent Lamp LED A22 - 2 Flange Shape Non-lighted Code Description F Round/Flat T Round/Projection G Round/Full-guard H Round/Half-guard C Square/Projection D Square/Full-guard S Round/Mushroom (30-dia. head) M Round/Mushroom (40-dia. head) Lighted ...
Page 9
... Description 10 SPST-NO 01 SPST-NC 11 SPST-NO + SPST-NC 20 DPST-NO 02 DPST- Illumination Color Code None Incandescent lamp A22 - - 3 Switch Action 4 Transformer (Lighted Type Only) Code Description M Momentary A Latching Description Red Green Yellow Blue Code Description None Without transformer *1 T1 110 VAC *2 T2 220 VAC *1) Operational voltage 115 VAC ...
Page 10
... A22L-CR A22L-DR A22L-CG A22L-DG A22L-CY A22L-DY A22L-CW A22L-DW A22L-CA A22L-DA Full-guard type Half-guard type A22-GR A22-HR A22-GG A22-HG A22-GY A22-HY A22-GW A22-HW A22-GA A22-HA A22-GB A22-HB Round/Mushroom type Round/Mushroom type (30-dia. head) (40-dia. head) A22-SR A22-MR A22-SG A22-MG A22-SY A22-MY A22-SW ...
Page 11
... VDC LED light Red A22-6DR Green A22-6DG Yellow (see note 2) A22-6DY Blue A22-6DA Note: 1. For transformer lighting, use the A22-24A . 2. Used when the Operational Unit color is yellow or white. Incandescent Rated voltage 6 VAC A22-5 Switch Unit (General-purpose Load) Non-lighted Switch action Momentary ...
Page 12
... Lighted models have the same dimensions as shown above, whether they are with transformers or without transformers. 12 For SPST-NO (SPST-NC) Switches 29.7 dia. 54.7 (see note 1) Projection Type A22-T, A22L-T 54.7 (see note 1) 40-dia. Mushroom Type A22-M 54.7 (see note 1) Square Full-guard Type A22-D, A22L-D 54 ...
Page 13
... SPST-NC) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat.No. A108-E1-1 (A22) Lighted (SPST-NO + SPST-NC) Contact Blocks Lamp Socket Panel Cutout Dimensions Note: When applying coating such as paint to the panel, the dimensions should be those after the application of coating ...