A165W-A2AY-24D-1 Omron, A165W-A2AY-24D-1 Datasheet - Page 20

SWITCH KNOB SQ 2-POS SPDT ILL

A165W-A2AY-24D-1

Manufacturer Part Number
A165W-A2AY-24D-1
Description
SWITCH KNOB SQ 2-POS SPDT ILL
Manufacturer
Omron
Series
A165Wr
Type
Standardr
Datasheets

Specifications of A165W-A2AY-24D-1

Circuit
SPDT
Switch Function
2 Position, Momentary
Contact Rating @ Voltage
5A @ 125VAC
Illumination
Illuminated
Illumination Type, Color
LED, Yellow
Illumination Voltage (nominal)
24 VDC
Mounting Type
Panel Mount
Termination Style
Quick Connect - .110" (2.8mm)
Panel Cutout Dimensions
16mm (Round)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A165WA2AY24D1
Z1368
Installation
J MOUNTING
After mounting the Pushbutton Unit to the panel, snap in the
Socket Unit from the back of the panel.
Panel mounting
Insert the Pushbutton Unit into the front of the panel, and fix the
lock ring and mounting nut from the terminal side.
Make sure that the lock ring is aligned with the thread of the case
and the edge of the lock ring is touching the panel.
Tighten the mounting nuts to a torque of 0.20 to 0.39 N • m (3 to
5 kgf • cm).
The maximum tightening torque is 0.39 N • m (5 kgf • cm).
Switch Mounting
Snap on the Switch Unit to the Pushbutton Unit.
Make sure the the Switch Unit is in the proper orientation when
snapping on to the Pushbutton Unit.
J SWITCH REMOVAL
Grip the part between the Switch holder of the case and the
Switch Unit using the A16Z-5080 Extractor, and pull to remove
the Switch Unit.
Case
A16Z-5080 Extractor
Edge
Thread
Panel
Lock ring
Mounting nut
21
J REPLACEMENT PARTS
Removal and installation of the Operating Part
J REMOVING THE LAMP
Removing from the Operating Part End
Removing from the Switch Unit End
The Lamp can be removed by hand once the Switch is removed
using the A16Z-5080 Extractor.
J INSTALLING THE LAMP
When mounting the Lamp, make sure it is facing the direction
shown in the following diagram. Insert the Lamp while matching
the protruding part of the Lamp and the small guides on the outer
surface of the case.
The Lamp can be mounted from the operating part end by using
the A16Z-5080 Extractor. The lamp can be mounted by following
the opposite procedure for removing the Lamp.
Protruding part
1. Remove the operating part as shown in the following
2. To attach the operating part, push until it clicks into place.
diagram. If the operating part cannot be removed by hand,
use the A3PJ-5080 Extractor.
Lamp
Grip the Lamp with the
A16Z-5080 Extractor and
pull to remove.
Operating section

Related parts for A165W-A2AY-24D-1