D2D-1100 Omron, D2D-1100 Datasheet - Page 6

SWITCH SPDT(DB) 16A DOOR INTRLOC

D2D-1100

Manufacturer Part Number
D2D-1100
Description
SWITCH SPDT(DB) 16A DOOR INTRLOC
Manufacturer
Omron
Series
D2Dr
Type
Door Interlock Switchr
Datasheets

Specifications of D2D-1100

Actuator Type
Round (Pin Plunger)
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
16A @ 125VAC
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .250" (6.3mm)
Operating Force
600gf
Contact Form
SPDB - NO / NC
Contact Rating
16 Amps
Actuator
Plunger
Contact Configuration
SPDT-1NO / 1NC
Contact Voltage Ac Max
250V
Contact Current Ac Max
16A
Switch Terminals
Quick Connect
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
UL, VDE, CSA,
Pole Throw Configuration
SP
Switch Function Configuration
N.O./N.C.
Current Rating (max)
16A
Operating Temp Range
-25C to 85C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D2D-1100
D2D1100
SW982
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
■ Pull-on Lock Models
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
Actuation
Apply operation force to the pin plunger in the direction it operates.
Applying forces laterally or from an oblique direction may damage the
pin plunger.
30
Screw Mounting
D2D-2000
Panel Mounting
D2D-2100
2. The operating characteristics are for operation in the A direction( )
Note: At pull-on lock operation.
Note: At pull-on lock operation.
Door Interlock Switch
TTP
(see
note)
TTP
(see
note)
Incorrect
OP
(see
note)
OP
(see
note)
FP
FP
OP
Correct
OP
TTP
TTP
Incorrect
D2D
22±0.1
40±0.1
8 dia.
8 dia.
10.4
25.2
10.4
25.2
30
30
16
A
A
4.3±0.05 dia.
1.8
Four quick-connect
terminals (#250)
2.0
31.7
Four quick-connect
terminals (#250)
5.8
33.6
6.35±0.1
6.35±0.1
21.2
12.4
12.4
13
Using Microloads
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
1.65
23.6
1.65
21.8
+0.1
0
+0.1
0
dia.
dia.
Momentary Operation
(Normal Operation)
OF max.
TTF max.
OT min.
FP max.
OP
TTP max.
30
24
12
5
0
0.1
Pull-on Lock Operation
OF max.
PT max.
OT min.
MD max.
FP max.
OP
TTP max.
Model
NC-OFF
NC-OFF
1
NO-ON
NO-ON
Model
15.1 ± 0.6 mm 11.1 ± 0.6 mm
Inoperable
range
D2D-2000
14.3 mm
16.5 mm
10
13.5 ± 0.6 mm
12.7 ± 0.6 mm
D2D-2000
26mA
14.3 mm
8.3 mm
2,000 gf
0.4 mm
1.5 mm
2 mm
Current (mA)
100
Operating
range
160mA
4.5 mm
200 gf
300 gf
600 gf
D2D-2100
10.3 mm
12.5 mm
1,000
9.5 ± 0.6 mm
8.7 ± 0.6 mm
D2D-2100
10.3 mm
4.3 mm

Related parts for D2D-1100