TSE3941-150G MG Chemicals, TSE3941-150G Datasheet - Page 3

ADHESIVE SEAL SIL WH FAST CURE

TSE3941-150G

Manufacturer Part Number
TSE3941-150G
Description
ADHESIVE SEAL SIL WH FAST CURE
Manufacturer
MG Chemicals
Series
RTVr
Type
Potting Compound, 1 Partr
Datasheets

Specifications of TSE3941-150G

Features
Thermally Conductive
Product
Silicones
Size
150 g
Container
Tube
Chemical Component
Silicone
Dispensing Method
Tube
Primary Type
Adhesive
Special Features
Flame Retardant, Thermally Conductive
Temperature, Rating
-55 to +200 °C
Time, Setting
5 min.
Weight
5.3 Oz.
For Use With/related Products
Non Corrosive
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
{ error: graphic file not found:
E:\TC_MSDS_5028\webapps\ehswww\WEB-
INF\bin\graphics\vkoJP01.bmp }
5. FIRE-FIGHTING MEASURES
FLASH POINT:
IGNITION TEMPERATURE:
FLAMMABLE LIMITS IN AIR - LOWER (%):
FLAMMABLE LIMITS IN AIR - UPPER (%):
SENSITIVITY TO MECHANICAL IMPACT:
SENSITIVITY TO STATIC DISCHARGE
EXTINGUISHING MEDIA
SPECIAL FIRE FIGHTING PROCEDURES
6. ACCIDENTAL RELEASE MEASURES
ACTION TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED
7. HANDLING AND STORAGE
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
STORAGE
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS
TSE 3941 - cartg (310ml - 510g)
SILICONE ELECTRONICS ADHESIVE
Sensitivity to static discharge is not expected.
All standard extinguishing agents are suitable.
Firefighters must wear NIOSH/MSHA approved positive pressure self-contained breathing
apparatus with full face mask and full protective clothing.
Wipe, scrape or soak up in an inert material and put in a container for disposal. Wash walking
surfaces with detergent and water to reduce slipping hazard. Wear proper protective equipment as
specified in the protective equipment section. Increase area ventilation.
Avoid contact with skin and eyes. Use only in well-ventilated areas. Remove contact lenses before
using sealant. Do not handle lenses until all sealant has been cleaned from the fingertips, nails and
cuticles. Residual sealant may remain on fingers for several days and transfer to lenses and cause
severe eye irritation. Keep away from children.
Store away from heat, sources of ignition, and incompatibles.
Eyewash stations; Showers; Exhaust ventilation
Page 3/8
132 °C; 270 °F
450 °C; 842 °F
Not applicable
Not applicable
No
Material Safety Data Sheet
Version: 1.3
11/10/2007