SBL2E-100IR NetBurner Inc, SBL2E-100IR Datasheet - Page 19

DUAL PORT SERIAL-ETHERNET

SBL2E-100IR

Manufacturer Part Number
SBL2E-100IR
Description
DUAL PORT SERIAL-ETHERNET
Manufacturer
NetBurner Inc
Series
SBL2er
Type
Server, Serial to Ethernetr
Datasheets

Specifications of SBL2E-100IR

Size
2.00" L x 1.20" W (50.8mm x 30.8mm)
Number Of I/os
10
Data Rate
115.2 Kbps
Interface Type
I2C, UART
Operating Voltage
3.3 V
Operating Current
300 mA
Operating Temperature Range
- 40 C to + 85 C
Board Size
1.2 in x 2 in
Data Bus Width
12 bit
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
For Use With/related Products
-
Lead Free Status / Rohs Status
 Details
Other names
Q5819275A
8. AT Commands
As an alternative to the web page configuration, you can configure the SBL2e over a serial port
using an AT command format. The configuration sequence is:
The AT command operation is different for configuration commands versus GPIO pin
programming commands. Please refer to “GPIO Server and Analog to Digital Readback” later in
this section for additional details.
8.1 Enter and Exit Command Mode
AT configuration commands can only be processed when the SBL2e is in “AT Command Mode”.
To enter AT command mode:
To exit command mode:
Exiting command mode with any changes terminate all existing TCP connections.
SBL2e Dual Serial-to-Ethernet User's Manual
Returns:
1. Enter command mode
2. Send configuration change commands
3. Save changes and exit
1. Pause for 1 second (send no data).
2. Send “+++”.
3. Wait for 1 second.
4. The device will respond with “\r\nOK”.
1. Wait 30 seconds for timeout, any changes will be lost.
2. Send “AT&X” or “ATO” to exit and discard any changes.
3. Send “AT&P” to exit and save new settings.
4. Send “AT&F” to reset all settings to factory default (does not save).
1, Returning to active connection
2, Returning to listening connection
3, Returning to active UDP mode
0, Returning to idle
Page 19