MT5600BA-V92-GB/IE Multi-Tech Systems, MT5600BA-V92-GB/IE Datasheet - Page 6

no-image

MT5600BA-V92-GB/IE

Manufacturer Part Number
MT5600BA-V92-GB/IE
Description
MODEM V.92 DATA/FAX WORLD
Manufacturer
Multi-Tech Systems
Series
MultiModem® IIr

Specifications of MT5600BA-V92-GB/IE

Data Format
V.92
Interface
RS-232
Voltage - Supply
9 V ~ 12 V
Mounting Type
Desktop
Package / Case
9.0" L x 6.2" W x 1.4" H (229mm x 158mm x 36mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1059
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Value:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G)
DS=n Dial Stored Telephone Number
En
Hn
In
L5
On
P
Mn Monitor Speaker Mode
n = 0–3
none
Dials a number previously stored in directory number n by the &Zn=x command.
Example: ATDS=3.
Echo Command Mode Characters
n = 0 or 1
1
E0
E1
Hook Control
n = 0 or 1
0
H0
H1
Information Request
n = 0–6
None
I0
I1
I2
I3
I4
I5
I6
Lists Current Operating Parameters
Note:
5
None
Displays the current values for the error correction, flow control, data compression, and
serial port speed commands. Example:
Note:
n= 0, 1, 2, or 3
1
M0
M1
M2
M3
Return Online to Data Mode
0 or 1
None
O0
O1
Pulse Dialing
P,T
T
Forces pulse (non-touch-tone) dialing until a T command or T dial modifier is received.
L5 is not supported by the MT5656ZDX. Use &V).
Use the &V command to display the other parameters.
Does not echo keyboard input to the terminal.
Does echo keyboard input to the terminal.
Goes on-hook (hang up) and terminate any &T test in progress.
Goes off-hook (make the phone line busy); enters command mode.
Displays the product code. Example: MT5600BA-V92.
Calculates ROM checksum; displays the least significant byte in decimal format.
Calculates ROM checksum and compares it to the prestored checksum, displays
OK if they match or ERROR if they don’t match.
Displays the firmware version and application codes.
Displays the OEM-defined identifier string in either binary or ASCII format.
Displays the regional or country code. Example: 098.
Displays the modem data pump model and internal code version.
Speaker is always off.
Speaker is on until the carrier signal is detected.
Speaker is always on when the modem is off-hook.
Speaker is off when receiving carrier and during dialing, but on during answering.
Exit online command mode and return to online data mode without a retrain.
Normally used after a +++ escape (see +++ escape sequence).
Exit online command mode and return to online data mode after a retrain.
atL5
&E2 &E3 &E15 $SB115200
OK
Chapter 2 – AT Commands
6