1585731 Phoenix Contact, 1585731 Datasheet - Page 2

no-image

1585731

Manufacturer Part Number
1585731
Description
HEAVYCON INSERT MODULE FML 2POS
Manufacturer
Phoenix Contact
Series
HEAVYCON® Mr
Datasheet

Specifications of 1585731

Connector Type
Module
Gender
Female
Number Of Positions
2
Termination Style
Screw
Voltage Rating
600V
Current Rating
70A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Size
-
Contact Type
-
Other names
HC-M-02-HS-70/22-MOD-BU
HC-M-02-HS-70/22-MOD-BU
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1585731
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Rated surge voltage
Ambient temperature (operation)
Number of positions
Mechanical characteristics
Conductor cross-section
Connection cross-section AWG
Stripping length of the individual wire
Tightening torque
Wire diameter including insulation
Hexagonal socket
Insertion/withdrawal cycles
General characteristics
Number of module slots
Connection method
Inflammability class acc. to UL 94
Pollution degree
Surge voltage category
Assembly instructions
Connection
Order No.: 1585731
8 kV
-40 °C ... 125 °C
2
14 mm² ... 22 mm²
4
11 mm + 1 (14 mm
12.5 mm + 1 (for 22 mm
4 Nm (for 14 mm
5 Nm (22 mm
10 mm
SW2,5
≥ 500
1
Axial screw connection
V0
3
III
Use 2.5 mm Allen wrenches for axial connection. Only for
stranded wires. For housing heights h ≥ 52 mm. Plug-in
connections may only be operated only when there is no load/
voltage.
Note regarding axial connection technology: Only for stranded
wires. The conductor cross-sections stated refer to the geometric
cross-section of the cable used.Use of cables with a geometric
cross-section very different from that of the cable's nominal cross-
section should be checked before use.The wiring space of the
axial screw method is designed for fine strand cables according
to VDE 0295 class 5. Deviating cable structures (e.g. class
6 cables) should be checked before use.Connection Before
starting to connect, ensure that the tapered screw is turned back
all the way (chamber is open). The cables must not be twisted.
The cores should be slid to the limit stop in the contact chamber
(until insulation touches contact). Hold cores in position and use
socket wrench to tighten. The used core end should be cut off
before connecting again. The connection screw may only be
retightened once to prevent the strands from breaking. To prevent
damage to the contact, the core / cable should be mechanically
intercepted at an appropriate distance from the connection
point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06
contains information on how to do this correctly.
2
)
2
... 16 mm
2
... 16 mm
2
)
2
)
2
)
Jan 27, 2011
Page 2 / 5