SI3010-FS Silicon Laboratories Inc, SI3010-FS Datasheet - Page 61

no-image

SI3010-FS

Manufacturer Part Number
SI3010-FS
Description
IC SI2401 LINE-SIDE DAA 16SOIC
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3010-FS

Data Format
V.92
Interface
Serial
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Baud Rates
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
336-1096

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3010-FS
Quantity:
1 218
Part Number:
SI3010-FS
Manufacturer:
VISHAY
Quantity:
1 000
Part Number:
SI3010-FS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI3010-FSR
Manufacturer:
SiliconLa
Quantity:
2 155
Part Number:
SI3010-FSR
Manufacturer:
VISHAY/威世
Quantity:
20 000
Register 17. International Control 2
Reset settings = 0000_0000
Bit
Name
Type
7
6
5
4
3
2
1
0
Bit
Reserved Read returns zero.
MCAL
Name
CALD
CALZ
ROV
OPE
BTE
BTD
CALZ
R/W
D7
Clear ADC Calibration.
0 = Normal operation.
1 = Clears the existing calibration data. This bit must be written back to 0 after being set.
Manual ADC Calibration.
0 = No calibration.
1 = Initiate manual ADC calibration.
ADC Auto-Calibration Disable.
0 = Enable auto-calibration.
1 = Disable auto-calibration.
Overload Protect Enable.
0 = Disabled.
1 = Enabled.
The OPE bit should always be cleared before going off-hook.
Billing Tone Detect Enable.
When set, the DAA can detect a billing tone signal on the line and maintain on off-hook state
through the billing tone. If a billing tone is detected, the BTD bit (Register 17) is set to indicate
the event. Writing this bit to zero clears the BTD bit.
0 = Billing tone detection disabled. The BDT bit is not function.
1 = Billing tone detection enabled. The BDT is functional.
Receive Overload.
This bit is set when the receive input has an excessive input level (i.e., receive pin goes below
ground). Writing a zero to this location clears this bit and the ROVI bit (Register 4, bit 6).
0 = Normal receive input level.
1 = Excessive receive input level.
Billing Tone Detected.
This bit is set if a billing tone is detected. Writing a zero to BTE clears this bit.
0 = No billing tone detected.
1 = Billing tone detected.
MCAL
R/W
D6
CALD
R/W
D5
D4
OPE
R/W
D3
Rev. 1.05
BTE
R/W
D2
Function
ROV
R/W
D1
BTD
D0
R
Si3018/19/10
61