SI3015-FS Silicon Laboratories Inc, SI3015-FS Datasheet - Page 45

no-image

SI3015-FS

Manufacturer Part Number
SI3015-FS
Description
SI2400 ISOMODEM LINE-SIDE
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3015-FS

Data Format
V.90
Interface
Serial
Voltage - Supply
3.3 V ~ 5 V
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Baud Rates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3015-FS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI3015-FSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Notes:
Register
S2C
S2D
1. These registers are explained in detail in the following section.
2. The ring detector will only detect ringing if the ring burst on/off times meet the settings in MNRP, MXRP, MNRU, ROT,
S26
S27
S28
S29
S2A
S2B
S2E
S2F
“S”
and REP.
Register
Address
(hex)
0x2C
0x2D
0x2A
0x2B
0x2E
0x2F
0x26
0x27
0x28
0x29
VTSOH V.22bis 2400 bps scrambled ones length high. Minimum length
VTSOL
Name
VTSO
DTTO
RTCT
RSO
FCD
SDL
DTL
IS
Table 28. S-Register Summary (Continued)
Function
V.22bis 1200 bps scrambled ones length. Minimum length of
time for transmission of 1200 bps scrambled binary ones by a
call mode V.22bis modem after the end of pattern S1 detection
(53.3 ms).
V.22bis 2400 bps scrambled ones length low. Minimum length of
time for transmission of 2400 bps scrambled binary ones by a
call mode V.22bis modem (5/3 ms units).
of time for transmission of 2400 bps scrambled binary ones by a
call mode V.22bis modem (256 5/3 ms units added to the time
specified by VTSOL).
Intrusion suspend. When S82[2:1] (IB) = 10b, this register sets
the length of time from when dialing begins that the off-hook
intrusion algorithm is blocked (suspended) (500 ms units).
Receive scrambled ones V.22bis (2400 bps) length.
Minimum length of time required for detection of scrambled
binary ones during V.22bis handshaking by the answering
modem after S1 pattern conclusion (5/3 ms units).
V.23 direct turnaround carrier length. Minimum length of time that
a master mode V.23 modem must detect carrier when searching
for a direct turnaround sequence (5/3 ms units). In the !7 alarm
mode, this register functions as pulse on time.
V.23 direct turnaround timeout. Length of time that the modem
searches for a direct turnaround carrier (5/3 ms units added to a
minimum time of 426.66 ms). In the !7 alarm mode, this register
functions as pulse off time.
V.23 slave carrier detect loss. Minimum length of time that a
slave mode V.23 modem must lose carrier before searching
for a reverse turnaround sequence (5/3 ms units). In the !7
alarm mode, this register functions as pulse interdigit time
(10 ms units).
V.23 reverse turnaround carrier timeout. Amount of time a slave
mode V.23 modem will search for carriers during potential
reverse turnaround sequences (5/3 ms units). In the !7 alarm
mode, this register functions as Handshake End to TX Data
delay (10 ms units).
FSK connection delay low. Amount of time delay added
between end of answer tone handshake and actual modem
connection for FSK modem connections (5/3 ms units).
Rev. 1.1
Si2400
Reset
0x0C
0xD2
0x0C
0x3C
0x78
0x08
0x00
0x18
0x08
0x84
45

Related parts for SI3015-FS