SH24D50 TELEDYNE, SH24D50 Datasheet - Page 3

Solid State Relays 50A 12-275VAC Load 3-32VDC Zero Cross

SH24D50

Manufacturer Part Number
SH24D50
Description
Solid State Relays 50A 12-275VAC Load 3-32VDC Zero Cross
Manufacturer
TELEDYNE
Datasheets

Specifications of SH24D50

Control Voltage Range
3 VDC to 32 VDC
Load Voltage Rating
12 VAC to 275 VAC
Load Current Rating
50 A
Mounting Style
SMD/SMT
Relay Type
HIPpak Solid State
Application
Used for high inductive loads or phase angle control applications
Brand/series
SH Series
Current, Leakage, Off-state
3 mA
Current, Rating
50 A
Current, Surge
720 A (Max.)
Dimensions
1.77 in. L x 0.29 in. W x 2.3 in. H
Function
Soft Start
Resistance, Thermal, Junction To Case
0.45 °C⁄W
Standards
cULus, CE
Temperature, Ambient, Maximum
80 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Screw
Voltage, Control
32 VDC
Voltage, Rating
275 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Peak Voltage (VDR Clamping)
Load Currrent Range (Resistive)
Maximum Surge Current Rating (Non-Repetitive)
On-State Voltage Drop
Output Power Dissipation (Max)
Zero-Cross Window (Typical)
Off-State Leakage Current
(+25°C ambient temperature unless otherwise specified)
SH24
SH48
SH60
25 output current
35 output current
50 output current
75 output current
95 output current
125 output current
25 output current
35 output current
50 output current
75 output current
95 output current
125 output current
25 output current
35 output current
50 output current
75 output current
95 output current
125 output current
SHXXR
SHXXD/A
SHXXR
SHXXD/A
OUTPUT (LOAD) SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
0.9x0.9xI + 0.0045xI
0.9x0.9xI + 0.0035xI
0.9x0.9xI + 0.016xI
0.9x0.9xI + 0.015xI
0.9x0.9xI + 0.012xI
0.9x0.9xI + 0.002xI
(450)
(950)
.005
.005
.005
.005
.005
.005
Min
1200
1600
1200
1700
2200
Max
600
110
150
350
500
720
±12
0.9
NA
25
40
60
90
3
1
2
2
2
2
2
2
Vpeak
Vpeak
Vpeak
Units
Arms
Arms
Arms
Arms
Arms
Arms
Vac
mA
mA
W
W
W
W
W
W
A
A
A
A
A
A
V
High Industrial Performance (HIPpak) Solid-State Relays
Turn-On Time (60 Hz)
Turn-Off Time (60 Hz)
Off-State dv/dt
Maximum di/dt (Non-Repetitive)
Operating Frequency
I
Junction-Case Thermal Resistance
Conducted Immunity Level
2
t for fuse matching (<10ms)
SHXXR
SHXXD
SHXXA
SHXXR/D
SHXXA
SHXXR
SHXXD/A
25 output current
35 output current
50 output current
75 output current
95 output current
125 output current
25 output current
35 output current
50 output current
75 output current
95 output current
125 output current
IEC/EN61000-4-4 (bursts)
SH24
SH48/SH60
IEC/EN61000-4-5 (surge)
SH24
SH48
SH60
4kV criterion A (with external VDR)
NEW Series SH
Output to 125A, 690 Vac
0.1
0.1
2kV criterion A
4kV criterion A
2kV criterion A
4kV criterion A
14400
24000
1250
2500
7200
0.04
24.9
24.9
0.45
0.25
500
400
800
600
8.3
8.3
1.7
0.6
0.4
0.3
50
SH\032005\Q1
°C/W
°C/W
°C/W
°C/W
°C/W
°C/W
V/µs
A/µs
A
A
A
A
A
A
ms
ms
ms
ms
ms
Hz
Hz
2
2
2
2
2
2
s
s
s
s
s
s

Related parts for SH24D50