... IP20 touch-proof fl aps • Connectors for power wiring and heat sinks available • Designed in conformity with EN60947-4-3 (IEC947-4-3) and EN60950/VDE0805 (Reinforced Insulation) Load Load Part No. Voltage Current SH24D25 12-275 Vac 25A SH24A25 12-275 Vac 25A 20-265 Vac/dc SH24D35 12-275 Vac ...
Page 2
... SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE High Industrial Performance (HIPpak) Solid-State Relays CONTROL CHARACTERISTICS Max Units 2.0 Vdc 5.0 Vdc Figure 3a — SH24R/D, SH48R/D relays 0.185 ( ) Figure 3b — SH24A, SH48A relays Figure 3c — SH60D relays NEW Series SH Output to 125A, 690 Vac © 2008 TELEDYNE RELAYS SH\102008\Q4 ...
Page 3
... Conducted Immunity Level 2 W IEC/EN61000-4-4 (bursts) SH24 SH48/SH60 NA ±12 Vac IEC/EN61000-4-5 (surge) SH24 SH48 3 mA SH60 4kV criterion A (with external VDR (800) 284-7007 • www.teledynerelays.com NEW Series SH Output to 125A, 690 Vac 0.04 ms 8.3 ms 24.9 ms 8.3 ms 24.9 ms 500 V/μs 50 A/μs 0.1 ...
Page 4
... Output-Case Isolation 4000 Insulation Resistance @500Vdc 1000 Rated Impulse Voltage Protection Level (CEI529) Vibration (10–55 Hz according to CE168) Shock (according to CD168) Housing Material PA6 UL94VO Baseplate Aluminum, nickel-plated © 2008 TELEDYNE RELAYS Max Units +80 °C +80 °C +125 °C +125 ° Vrms Vrms MΩ ...
Page 5
... Figure 5a — 25A output power Figure 5c — 50A output power Figure 5e — 95A output power 12°C/W corresponds to a relay without heat sink 6°C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12) © 2008 TELEDYNE RELAYS High Industrial Performance (HIPpak) Solid-State Relays THERMAL CURVES Figure 5b — ...
Page 6
... Fastons: Call us Special kit for high current AWG2 / 35mm 2 AWG0 / 50mm 2 NEW Series SH Output to 125A, 690 Vac With special adaptation for high-voltage relays Screwdriver Recommended Type Torque N.m Pozidriv 2 0.8 Screwdriver Recommended Type Torque N.m Pozidriv 2 1.2 © 2008 TELEDYNE RELAYS SH\102008\Q4 ...
Page 7
... HIPpak SSRs must be mounted on heat sinks. A large range of heat sinks is available. For heat-sink mounting, use thermal grease or a thermal pad with high conductibility specifi ed by Teledyne. DIN Rail Adapter Teledyne P/N DL12 Typical Loads (Random) SH relays with random turn-on are designed for high inductive loads or phase angle control applications. ...
Page 8
... SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or interconnections may not be under Teledyne’s control, it shall be the responsibility of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. • ...