Specifications of 450-0012

Wireless Frequency
2.4 GHz
Operating Voltage
3.3 V
Output Power
100 mW
Antenna
U.FL Connector
Operating Temperature Range
- 40 C to + 85 C
For Use With/related Products
MSP430
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The information in this document is subject to change without notice.
Confirm the data is current by downloading the latest revision from www.lsr.com.
330-0001-R2.3
Module
Pin
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
Name
GND
P7.3
P8.6
P8.5
P8.4
P8.3
P8.2
P8.1
P8.0
P1.2
P7.7
P1.0
P1.1
P2.0
P2.1
MCU
N/A
Pin
59
66
65
64
63
62
61
60
19
17
18
25
26
Copyright © 2009-2011 LS Research, LLC
8
Type
GND
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
General-purpose digital I/O
Timer1_A3 CCR2 capture: CCI2B input, compare: Out2
output
General-purpose digital I/O
Timer1_A3 CCR1 capture: CCI1B input, compare: Out1
output
General-purpose digital I/O
Timer1_A3 CCR0 capture: CCI0B input, compare: Out0
output
General-purpose digital I/O
Timer0_A5 CCR4 capture: CCI4B input, compare: Out4
output
General-purpose digital I/O
Timer0_A5 CCR3 capture: CCI3B input, compare: Out3
output
General-purpose digital I/O
Timer0_A5 CCR2 capture: CCI2B input, compare: Out2
output
Ground
General-purpose digital I/O
Timer0_A5 CCR1 capture: CCI1B input, compare: Out1
output
General-purpose digital I/O
Timer0_A5 CCR0 capture: CCI0B input, compare: Out0
output
General-purpose digital I/O with port interrupt
TA0 CCR1 capture: CCI1A input, compare: Out1 output
BSL receive input
General-purpose digital I/O
Analog input
General-purpose digital I/O with port interrupt
Timer0_A5 clock signal TACLK input
ACLK output
General-purpose digital I/O with port interrupt
Timer0_A5 CCR0 capture: CCI0A input, compare: Out0
output BSL transmit output
General-purpose digital I/O with port interrupt
Timer1_A3 clock signal TA1CLK input
MCLK output
General-purpose digital I/O with port interrupt
Timer1_A3 CCR0 capture: CCI0A input, compare: Out0
output
ProFLEX01 TRANSCEIVER MODULE
Description
DATASHEET
Page 9 of 31