Light to Digital Converters Light to Digital with I2C

TSL2561T

Manufacturer Part Number
TSL2561T
Description
Light to Digital Converters Light to Digital with I2C
Manufacturer
TAOS
Datasheets

Specifications of TSL2561T

Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 30 C
Mounting Style
SMD/SMT
Package / Case
TMB
Response Time
400ms
Output Current
6mA
Supply Voltage Range Dc
2.7V To 3.6V
Supply Current
0.6mA
Operating Temperature Range
-30°C To +70°C
Operating Temperature Min
-30°C
Rohs Compliant
Yes
Operating Temperature Max
70°C
Sensor Output
I2C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSL2561T
Manufacturer:
IR
Quantity:
836
Part Number:
TSL2561T
Manufacturer:
AMS
Quantity:
20 000
Part Number:
TSL2561T
0
TSL2560, TSL2561
LIGHT-TO-DIGITAL CONVERTER
TAOS059D − DECEMBER 2005
Functional Block Diagram
Detailed Description
2
Copyright E 2005, TAOS Inc.
V
DD
The TSL2560 and TSL2561 are second-generation ambient light sensor devices. Each contains two integrating
analog-to-digital converters (ADC) that integrate currents from two photodiodes. Integration of both channels
occurs simultaneously. Upon completion of the conversion cycle, the conversion result is transferred to the
Channel 0 and Channel 1 data registers, respectively. The transfers are double-buffered to ensure that the
integrity of the data is maintained. After the transfer, the device automatically begins the next integration cycle.
Communication to the device is accomplished through a standard, two-wire SMBus or I
Consequently, the TSL256x device can be easily connected to a microcontroller or embedded controller. No
external circuitry is required for signal conditioning, thereby saving PCB real estate as well. Since the output
of the TSL256x device is digital, the output is effectively immune to noise when compared to an analog signal.
The TSL256x devices also support an interrupt feature that simplifies and improves system efficiency by
eliminating the need to poll a sensor for a light intensity value. The primary purpose of the interrupt function is
to detect a meaningful change in light intensity. The concept of a meaningful change can be defined by the user
both in terms of light intensity and time, or persistence, of that change in intensity. The TSL256x devices have
the ability to define a threshold above and below the current light level. An interrupt is generated when the value
of a conversion exceeds either of these limits.
= 2.7 V to 3.5 V
ADDR SEL
Address Select
Visible and IR
Channel 0
Channel 1
IR Only
r
www.taosinc.com
Command
Register
Two-Wire Serial Interface
A/D Converter
Integrating
Register
ADC
r
Interrupt
The LUMENOLOGY r Company
2
C serial bus.
INT
SCL
SDA

Related parts for TSL2561T