FPGA - Field Programmable Gate Array 60K System Gates

AGLP060V2-CSG289

Manufacturer Part Number
AGLP060V2-CSG289
Description
FPGA - Field Programmable Gate Array 60K System Gates
Manufacturer
Actel
Datasheet

Specifications of AGLP060V2-CSG289

Processor Series
AGLP060
Core
IP Core
Number Of Macrocells
512
Maximum Operating Frequency
250 MHz
Number Of Programmable I/os
4
Data Ram Size
4608 bit
Supply Voltage (max)
1.575 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Development Tools By Supplier
AGLP-Eval-Kit, AGL-Dev-Kit-SCS, Silicon-Explorer II, Silicon-Sculptor 3, SI-EX-TCA, Flashpro 4, Flashpro 3, Flashpro Lite
Mounting Style
SMD/SMT
Supply Voltage (min)
1.14 V
Number Of Gates
60 K
Package / Case
CSP-289
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
IGLOO PLUS DC and Switching Characteristics
JTAG 1532 Characteristics
Table 2-100 • JTAG 1532
Table 2-101 • JTAG 1532
2- 78
Parameter
t
t
t
t
t
t
F
t
t
t
Note:
Parameter
t
t
t
t
t
t
F
t
t
t
Note:
DISU
DIHD
TMSSU
TMDHD
TCK2Q
RSTB2Q
TRSTREM
TRSTREC
TRSTMPW
DISU
DIHD
TMSSU
TMDHD
TCK2Q
RSTB2Q
TRSTREM
TRSTREC
TRSTMPW
TCKMAX
TCKMAX
For specific junction temperature and voltage supply levels, refer to
For specific junction temperature and voltage supply levels, refer to
Commercial-Case Conditions: T
Commercial-Case Conditions: T
JTAG timing delays do not include JTAG I/Os. To obtain complete JTAG timing, add I/O buffer delays to
the corresponding standard selected; refer to the I/O timing characteristics in the
Characteristics" section on page 2-15
Timing Characteristics
1.5 V DC Core Voltage
1.2 V DC Core Voltage
Test Data Input Setup Time
Test Data Input Hold Time
Test Mode Select Setup Time
Test Mode Select Hold Time
Clock to Q (data out)
Reset to Q (data out)
TCK Maximum Frequency
ResetB Removal Time
ResetB Recovery Time
ResetB Minimum Pulse
Test Data Input Setup Time
Test Data Input Hold Time
Test Mode Select Setup Time
Test Mode Select Hold Time
Clock to Q (data out)
Reset to Q (data out)
TCK Maximum Frequency
ResetB Removal Time
ResetB Recovery Time
ResetB Minimum Pulse
J
J
= 70°C, Worst-Case VCC = 1.425 V
= 70°C, Worst-Case VCC = 1.14 V
for more details.
Description
Description
R ev i sio n 1 1
Table 2-6 on page 2-6
Table 2-6 on page 2-6
25.00
TBD
1.00
2.00
1.00
2.00
8.00
0.58
0.00
Std.
11.00
30.00
15
TBD
Std.
1.50
3.00
1.50
3.00
9.00
1.18
0.00
for derating values.
for derating values.
"User I/O
Units
MHz
Units
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns

Related parts for AGLP060V2-CSG289