LIS331DLM STMicroelectronics, LIS331DLM Datasheet - Page 30
LIS331DLM
Manufacturer Part Number
LIS331DLM
Description
Board Mount Accelerometers DGTL OUTPT MTN SEN MEMS ULTRA LO PWR
Manufacturer
STMicroelectronics
Datasheet
1.LIS331DLM.pdf
(38 pages)
Specifications of LIS331DLM
Sensing Axis
X, Y, Z
Acceleration
2 g, 4 g, 8 g
Digital Output - Number Of Bits
8 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Shutdown
Yes
Package / Case
LGA-16
Output Type
Digital
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LIS331DLMTR
Manufacturer:
STMicroelect
Quantity:
4 650
Part Number:
LIS331DLMTR
Manufacturer:
ST
Quantity:
20 000
Register description
7.9
7.10
7.11
7.12
30/38
STATUS_REG (27h)
Table 34.
Table 35.
OUT_X (29)
X-axis acceleration data. The value is expressed as two’s complement with 8 bit data
representation right justified.
OUT_Y (2Bh)
Y-axis acceleration data. The value is expressed as two’s complement with 8 bit data
representation right justified.
OUT_Z (2Dh)
Z-axis acceleration data. The value is expressed as two’s complement with 8 bit data
representation right justified.
ZYXOR
ZOR
YOR
XOR
ZYXDA
ZDA
YDA
XDA
ZYXOR
STATUS_REG register
STATUS_REG description
X, Y and Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data has overwritten the previous one before it was read)
Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Z-axis has overwritten the previous one)
Y axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Y-axis has overwritten the previous one)
X axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the X-axis has overwritten the previous one)
X, Y and Z axis new data available. Default value: 0
(0: a new set of data is not yet available; 1: a new set of data is available)
Z axis new data available. Default value: 0
(0: a new data for the Z-axis is not yet available;
1: a new data for the Z-axis is available)
Y axis new data available. Default value: 0
(0: a new data for the Y-axis is not yet available;
1: a new data for the Y-axis is available)
X axis new data available. Default value: 0
(0: a new data for the X-axis is not yet available;
1: a new data for the X-axis is available)
ZOR
YOR
Doc ID 15102 Rev 4
XOR
ZYXDA
ZDA
YDA
LIS331DLM
XDA