Specifications of ASDXRRX005ND7A5

Operating Pressure
+/- 0.18 psi
Pressure Type
Differential
Accuracy
+/- 2 %
Output Type
Digital
Mounting Style
DIP
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 20 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
3.5 mA
Package / Case
DIP-8
Digital Output - Bus Interface
I2C
Digital Output - Number Of Bits
14
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
±
DESCRIPTION
The ASDX Series is a Silicon Pressure Sensor offering either
an I
specified full scale pressure span and temperature range.
The ASDX is fully calibrated and temperature compensated for
sensor offset, sensitivity, temperature effects and non-linearity
using an on-board Application Specific Integrated Circuit
(ASIC). Calibrated output values for pressure are updated at
approximately 1 kHz.
The standard ASDX is calibrated over the temperature range
of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
2
C or SPI digital interface for reading pressure over the
Output options: I
Precision ASIC conditioning and temperature
compensated over 0 °C to 85 °C [32 °F to 185 °F]
temperature range
Low operating voltage
Absolute, differential and gage types
Pressure ranges from 10 inches H
Standard calibrations in inches H
bar, kPa
Total error band of ±2.0% of full scale span maximum
RoHS compliant
2
C- or SPI-compatible 12-bit digital
2
0, cm H
2
0 to 100 psi
2
0, psi, mbar,
These sensors are available to measure absolute, differential
and gage pressures. The absolute versions have an internal
vacuum reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The ASDX Series sensors are intended for use with non-
corrosive, non-ionic working fluids such as air and dry gases.
They are designed and manufactured according to standards
in ISO 9001.
POTENTIAL APPLICATIONS
Flow calibrators
Ventilation and air flow monitors
Gas flow instrumentation
Sleep apnea monitoring and therapy equipment
Barometry
Pneumatic controls
HVAC

Related parts for ASDXRRX005ND7A5

ASDXRRX005ND7A5 Summary of contents

Page 1

... DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering either SPI digital interface for reading pressure over the specified full scale pressure span and temperature range. The ASDX is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects and non-linearity using an on-board Application Specific Integrated Circuit (ASIC) ...

Page 2

... Ratiometricity of the sensor (the ability of the output to scale to the input voltage) is achieved within the specified operating voltage for each option. Other custom supply voltages are available, please contact Honeywell Customer Service. 4. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin may cause electrical failure. ...

Page 3

... Future Option Notes: 13. Other package combinations are possible, please contact Honeywell Customer Service. 14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical representation of each calibration ...

Page 4

... Figure 3. Completed Catalog Listing Example ASDXAVX001PG2A3 pressure port, 1 psi gage output (Address 0x28), 10% to 90% calibration at 3.3 Vdc operation. 4 www.honeywell.com/sensing B Calibration 95% Digital Counts (dec) 0 819 1638 8192 14746 15565 16383 ASDXAVX001PG2A3 Output vs Pressure Digital Counts (hex) 0x0000 0x0333 0x0666 ...

Page 5

... MISO supply power supply ground not used do not connect in the application digital input slave select supply power supply source not used do not connect in the application not used do not connect in the application Honeywell Sensing and Control 5 ...

Page 6

... In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing ...

Related keywords