2CU15R Altech, 2CU15R Datasheet - Page 8

Circuit Breakers 15A C Characteristic UL 1077 2 POLE

2CU15R

Manufacturer Part Number
2CU15R
Description
Circuit Breakers 15A C Characteristic UL 1077 2 POLE
Manufacturer
Altech
Series
Rr
Datasheet

Specifications of 2CU15R

Product Type
Circuit Breakers
Current Rating
15 Amps
Voltage Rating
277 VoltsAC
Trip Time
0.1 s
Mounting Style
DIN Rail
Termination Style
Screw
Circuit Function
Supplementary Protectors
Product
Thermal Magnetic Circuit Breakers
Number Of Poles
2 Poles
Actuator Type
Handle
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Accessories
R-Series
Supplementary
Protector
Shunt Trip
Undervoltage Trip
E301611
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
Accessories can be factory or field mounted on R-Series supplementary protectors for enhanced
control and monitoring capabilities. Field mounting kits include all necessary parts and instruc-
tions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the
outside position). The mounting arrangement links the internal latch-pins for the tripping
mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting.
Neutral
Pole
Shunt Trip and
Undervoltage Trip
Auxiliary
Contact
Lock-out Adapter
(uses small suitcase lock)
Standard Pack:
Weight:
* Reset-Hold Voltage = 0.85 x V
Standard Pack:
Weight:
Standard Pack:
Weight:
Standard Pack:
Weight:
Description
Yellow
Description
AC Coil:
12V AC
24V AC
48V AC
60V AC
110V AC
120V AC
230V AC
277V AC
400V AC
DC Coil:
12V DC
24V DC
48V DC
110V DC
Description
Neutral
Description
1 x CO
2 x CO
1 x CO, 1 Signal
& Test Button
1.25kg (2.77 lb.)
1.1kg (2.43 lb.)
H1COR: 0.5kg (1.32 lb.); H2COR, HSTCOR: 0.72kg (1.59 lb.)
50g (1.76 oz.)
(63A/480Y/277 VAC)
(4A/230 VAC)
10
10
15
10
Cat. No.
Type/Cat. No.
ALTN2
Cat. No.
Type/
EASS2
Shunt Trip
FA110ACR
FA120ACR
FA230ACR
FA277ACR
FA400ACR
FA110DCR
FA12ACR
FA24ACR
FA48ACR
FA60ACR
FA12DCR
FA24DCR
FA48DCR
Type/
H1COR
H2COR
HSTCOR
Cat. No.
Type/
E
; Drop-Out Voltage = 0.2 x V
Terminal Size - min/max
Terminal Torque - min/max
AWG 3
25mm
Cable
Max
AWG 12
Operational
2.5mm
16.8 - 26.4V
33.6 - 52.8V
16.8 - 26.4V
33.6 - 52.8V
8.4 - 13.2V
161 - 253V
194 - 305V
280 - 440V
8.4 - 13.2V
Cable
77 - 121V
84 - 132V
77 - 121V
Max
42 - 66V
Voltage
2
2
E
AWG 12
2.5mm
AWG 20
Cable
Cable
0.5mm
Min
Min
Coil Current
2.5 mm
1.5 Nm (12 lb. in.) / 2 Nm (17.5 lb. in.)
2
Rated
2
~0.7A
~0.5A
~0.5A
2.8A
0.8A
0.5A
0.6A
0.5A
0.6A
~6A
6A
3A
2A
2
(12 AWG) / 25mm
17.5 lb-in
Torque
Torque
0.5Nm
2Nm
Max
Max
4 lb-in
Undervoltage Trip*
Type/Cat. No.
UV110ACR
UV120ACR
UV230ACR
UV277ACR
UV400ACR
UV110DCR
UV12ACR
UV24ACR
UV48ACR
UV60ACR
UV12DCR
UV24DCR
UV48DCR
2
Torque
12 lb-in
Torque
1.5Nm
0.33Nm
(3 AWG)
3 lb-in
Min
Min
17