B88069X1470B502 EPCOS Inc, B88069X1470B502 Datasheet - Page 3

Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors T33-A350X

B88069X1470B502

Manufacturer Part Number
B88069X1470B502
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors T33-A350X
Manufacturer
EPCOS Inc
Datasheet

Specifications of B88069X1470B502

Dc Breakover Voltage (nominal)
350 V
Number Of Electrodes
3
Termination Style
Through Hole
Dimensions
6 mm D x 8.1 mm L
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dimensional drawing
Cautions and warnings
KB AB E / KB AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
1)
2)
3)
4)
5)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
Surge arrester
3-electrode arrester
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Test according to ITU-T Rec. K.12
Tip or ring electrode to center electrode
Total current through center electrode, half value through
tip respectively ring electrode.
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Page 3 of 4
Not to scale
Dimensions in mm
Non controlled document
B88069X1470B502
Issue 04 / 2007-03-29
T33-A350X