B88069X4180B502 EPCOS Inc, B88069X4180B502 Datasheet

Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors ES 300XP

B88069X4180B502

Manufacturer Part Number
B88069X4180B502
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors ES 300XP
Manufacturer
EPCOS Inc
Datasheet

Specifications of B88069X4180B502

Peak Pulse Current
5 KA
Dc Breakover Voltage (nominal)
300 V
Number Of Electrodes
2
Termination Style
Radial
Dimensions
4.7 mm D x 4.7 mm L
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Surge arrester
2-electrode arrester
Series/Type:
Ordering code:
Version/Date:
Version:
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Identification/Classification 2:
(header 2 + bottom left header bar)
Ordering code:
(top right header bar)
Series/Type:
(top right header bar)
Preliminary data (optional):
(if necessary)
Department:
Date:
© EPCOS AG 2006. Reproduction, publication and dissemination of this document, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
ES300XP
B88069X4180B502
Issue 03 / 2006-09-27
6
Surge arrester
2-electrode arrester
B88069X4180B502
ES300XP
Issue 03 / 2006-09-27
KB AB E / KB AB PM

Related parts for B88069X4180B502

B88069X4180B502 Summary of contents

Page 1

... Series/Type: (top right header bar) Preliminary data (optional): (if necessary) Department: Date: © EPCOS AG 2006. Reproduction, publication and dissemination of this document, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Surge arrester 2-electrode arrester B88069X4180B502 ES300XP Issue 03 / 2006-09-27 ...

Page 2

... Important notes at the end of this document. Applications Modem XDSL-splitter Tuner 300 ± 15 < 500 < 450 < 600 < 550 2.5 5 > 1 < < 0.5 ~ 130 ~ 0.3 -40 ... +90 40/ 90 300 Series 300 - Nominal voltage YY - Year of production O - Non radioactive Page B88069X4180B502 ES300XP Ω °C Issue 03 / 2006-09-27 ...

Page 3

... Surge arresters may be used only within their specified values. In case of overload, the head contacts may fail or the component may be destroyed. Damaged surge arresters must not be re-used Please read Cautions and warnings and Important notes at the end of this document. Not to scale Dimensions in mm Non controlled document Page B88069X4180B502 ES300XP Issue 03 / 2006-09-27 ...

Page 4

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical ...

Related keywords