B59980C80A70 EPCOS Inc, B59980C80A70 Datasheet - Page 12

Thermistors - PTC PTC Thermistor C 980A 80A 70 5x1

B59980C80A70

Manufacturer Part Number
B59980C80A70
Description
Thermistors - PTC PTC Thermistor C 980A 80A 70 5x1
Manufacturer
EPCOS Inc
Type
PTCr
Datasheet

Specifications of B59980C80A70

Resistance
25 Ohms
Tolerance
25 %
Operating Temperature Range
- 40 C to + 125 C
Current Rating
50 mA
Voltage
63 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
B59980C0080A070
Mounting
Operation
Please read Cautions and warnings and
Important notes at the end of this document.
Overcurrent protection
Leaded disks, coated, 63 V
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Page 12 of 15
C910 ... C990

Related parts for B59980C80A70