Varistors 150V RMS 40MM Varistor B40K150

B72240B151K1

Manufacturer Part Number
B72240B151K1
Description
Varistors 150V RMS 40MM Varistor B40K150
Manufacturer
EPCOS Inc
Type
MOVr
Datasheets

Specifications of B72240B151K1

Voltage Rating Dc
200 V
Voltage Rating Ac
130 V
Clamping Voltage
395 V
Peak Surge Current
40 KA
Capacitance
4800 pF
Operating Temperature Range
- 40 C to + 85 C
Mounting
Screw
Tolerance
10 %
Brand/series
E Series
Current, Peak
40000 A
Current, Surge
40000 A
Dimensions
60 mm W x 55 mm H x 14 mm T
Electric Strength
≥2.5 kV (RMS) (Min.)
Energy Rating
360 Joules
Mounting Style
Leaded
Package
Screw
Power Rating
1.4 W
Resistance, Insulation
≥10 Megohms (Min.)
Technology
Metal Oxide
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-40 °C
Terminal Type
Screw
Voltage, Ac
150 VAC
Voltage, Clamping
395 V
Voltage, Dc
200 VDC
Voltage, Operating
150 Vrms⁄200 VDC
Voltage, Varistor
240
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
B72240B0151K001
Reliability data
Test
Varistor voltage
Clamping voltage
Max. DC operating voltage The maximum allowable DC operating
Surge current derating,
8/20 µs
Fast temperature cycling
Damp heat, steady state
Note:
UCT = Upper category temperature
LCT = Lower category temperature
Please read Cautions and warnings and
Important notes at the end of this document.
Block varistors
HighE series
Test methods/conditions
The voltage between two terminals with
the specified measuring current applied
is called V
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
voltage V
applied for 1000 ±48 h.
The leakage current I
is recorded.
Then the specimen shall be stored at
room temperature and normal humidity
for 1 to 2 h.
Thereafter, the change of V
measured.
10 surge currents (8/20 µs), unipolar,
interval ≥60 s, amplitude correspond-
ing to derating curve for 10 impulses
at 20 µs
IEC 60068-2-14, test Na, LCT/UCT,
dwell time 120 min, 5 cycles
IEC 60068-2-78
The specimen shall be subjected to
40 ±2 °C, 90 to 95% r. H. for 56 ±2 days
with 10% of the maximum continuous
DC operating voltage V
Then stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of V
measured.
DC
v
(1 mA
at UCT +5/–0 °C is
DC
8
@ 0.2 … 2 s).
leak
DC
11/07
(t) during test
.
v
v
shall be
shall be
Requirement
To meet the specified value.
To meet the specified value.
I
|
|
(measured in direction
of surge current)
No visible damage
|
No visible damage
|
leak
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
(t = 1000 h) ≤ I
|
|
|
|
≤10%
≤10%
≤10%
≤10%
leak
(t = 0 h)

Related parts for B72240B151K1