FGS.1M.308.XLMT LEMO, FGS.1M.308.XLMT Datasheet - Page 7

Circular Metric Connectors 8P STRT PLUG FEMALE CRIMP ARCTIC GRIP

FGS.1M.308.XLMT

Manufacturer Part Number
FGS.1M.308.XLMT
Description
Circular Metric Connectors 8P STRT PLUG FEMALE CRIMP ARCTIC GRIP
Manufacturer
LEMO
Series
M Seriesr
Datasheet

Specifications of FGS.1M.308.XLMT

Product Type
Connectors
Contact Style
Socket (Female)
Shell Style
Plug
Number Of Contacts
8
Mounting Style
Cable
Termination Style
Crimp
Contact Plating
Nickel / Gold
Current Rating
5 A
Voltage Rating
1.3 kV
Mating Style
Ratchet
Ingress Protection
IP68
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Assembly instructions for plugs and sockets
2
2
L
S
T
± 0.5
± 0.5
FG
PH
PB
± 0.2
Crimp
Heat
Crimp
Steel tie-wrap band (~3 mm wide)
Steel tie-wrap band (~3 mm wide)
1
Heat
2
2
1.
2.
2.1 With shielded cables, widen and pull the shield all the way
2.2 Arrange the conductor-contact assemblies according to
2.3 Bring the shield around the rear of connector. Secure it with
2.4 Put the heatshrink boot in place and heat gently until it
Cable preparation
First place the heatshrink
boot
the cable accor ding to dim-
ensions of the table, then
widen the shield.
Cable termination
to the back.
Fix the appropriate positioner onto the crimping tool and set
the selector to the number corresponding to the AWG of
the conductor used as indicated on the positioner label. Fit
the conductor into the contact ➁; make sure it is visible
through the contact’s inspection hole.
Slide the conductor-contact assembly into the open
crimping tool; make sure that the contact is pushed fully
into the positioner. Close the tool.
Remove from crimping tool and check that conductor is
secure in contact and shows in inspection hole.
the markings, into the rear cable seal. Push them deeply
into the insulator, using tweezers if necessary; check that
all the contacts are correctly located in the insulator: 1) by
verifying the alignment of the contacts at the front of the
insulator and 2) by gently pulling on each conductor.
Verification should also be made using the appropriate
retention testing tool.
a band-it tie-wrap (not furnished) to fix the shield in place.
Cut off the possible shield surplus.
retracts.
over the cable. Strip
1
1
Note : dimensions are in mm.
Series
0M
1M
2M
20
20
20
L
15
15
15
S
3.5
3.5
3.5
T