Circular MIL / Spec Connectors SEALING GASKET 10SL

10-040450-010

Manufacturer Part Number
10-040450-010
Description
Circular MIL / Spec Connectors SEALING GASKET 10SL
Manufacturer
Amphenol
Series
97 Seriesr
Datasheet

Specifications of 10-040450-010

Mil Type
MIL-DTL-5015
Product Type
Accessories
Shell Size
10S, 10SL
Number Of Contacts
1
Termination Style
Solder Lug
Shell Plating
Silver
Current Rating
40 A to 200 A
Body Material
Synthetic Rubber
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Assembly Instructions
for 10-305200 & 10-74900 cable clamps
The 10-305200 cable clamp and MS3420A sleeve illustrated are used only on
the rear of MS-A or C type connectors. The 10-74900 clamp and grommet
assembly can only be used on special feed-thru applications involving dummy
shells, part numbers 10-37090 and 10-113276.
10-305200 Cable Clamp & MS3420A Sleeve
10-74900 Clamp and Grommet Assembly
4
3
3
2
1. Clamping Nut
2. Tapered Sleeve
3. Grommet
1. Clamping Nut
2. Tapered Sleeve
3. Gland
4. Reducing or
2
Telescoping Sleeve
1
1
61
ASSEMBLY
Both clamps are shipped from the factory with lubricant
conforming to MIL-G-3278. Remove any dirt or foreign
material from components with ethyl alcohol and relubri-
cate as outlined under “lubrication.” Place the clamping
nut (1) on the wire bundle or cable with the threads facing
toward the connector or dummy shell. Position the
tapered sleeve (2) on the bundle or cable with the narrow
portion toward the clamping nut (1). Next install either the
gland (3) used with the 10-305200 clamp or thread each
wire through the grommet (3) used with the 10-74900
clamp. Dependent on the application, the wire bundle or
cable is fed through the dummy shell, or the wire ends
are soldered to the connector contacts. Move the compo-
nents forward in the reverse order of preliminary assem-
bly. (In applications where grommets (3) are used, seat
the grommet against the undercut in the back shell
before bringing the tapered sleeve (2) up against it).
Insure proper positioning of glands (3) or grommets (3),
tapered sleeves (2) and clamping nuts (1). Tighten the
clamp using a strap wrench until a metal to metal seat is
obtained.

Related parts for 10-040450-010