F2W2SC-1002 FCT Electronics, F2W2SC-1002 Datasheet - Page 3

no-image

F2W2SC-1002

Manufacturer Part Number
F2W2SC-1002
Description
D-Subminiature Connectors 2W2 PCB SOCKET MIXED GENDER
Manufacturer
FCT Electronics
Datasheet

Specifications of F2W2SC-1002

Product
Mixed Contact Hoods & Connectors
Number Of Positions / Contacts
2
Current Rating
5 A
Contact Plating
Gold over Nickel
Shell Plating
Yellow Chromate
Shell Size
1
Gender
Female
Mounting Style
Through Hole
Mounting Angle
Straight
Termination Style
Solder Pin
Contact Arrangement
2W2
Contact Material
Copper Alloy
Operating Temperature Range
- 55 C to + 155 C
Wire Size (awg)
20
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AuroPur High Performance Gold Plating
AuroPur Hochleistungs-Goldbeschichtung
FCT is introducing a new nickel phosphorous gold plating (min 0,1 µm
Au over 2-4 µm chemical NiP ) which has better qualities than standard
platings.
Connectors and Contacts with nickel phosphorus gold plating have been
tested in accordance with DIN 41626, part 1 and DIN 41652 part 2. A
relevant test report is available on request:
Sales Team FCT
sales@fctgroup.com
General Characteristics and Advantages of AuroPur High Performance Gold plating
Allgemeine Eigenschaften und Vorteile der AuroPur Hochleistungs-Goldbeschichtung
+ High abrasion resistance
+ Very good corrosion resistance
+ Low thermal contact resistance, very good contact characterisics
+ Excellent solderability
+ Even plating density
+ RoHs conform
+ Non-magnetic on request
Test Construction and Conditions
Testaufbau und -bedingungen
+ Contact resistance in accordance with DIN 41640 part 4 (Start Value /
+ Mechanical durability in accordance with DIN 41640 part 21 (250
+ Industrial atmosphere in accordance with DIN 41640 part 72 (Exposure
+ Optical testing in accordance with DIN 41640 part 2
+ Solderability in accordance with DIN IEC 68 part 2-20
+ Micro-impedance measuring device EMT 328
+ Corrosion test chamber K350 + TOX gas monitor 7100 (TZO Leipzig)
+ Solder bath in accordance with DIN IEC part 2-20
+ Durchgangswiderstand nach DIN 41640 Teil 4 (Anfangswert / Wert nach
+ Mechanische Lebensdauer nach DIN 41640 Teil 21 (250 Steckzyklen)
+ Industrieatmosphäre nach DIN 41640 Teil 72 (Belastung durch
+ Sichtprüfung nach DIN 41640 Teil 2
+ Lötbarkeit nach DIN IEC 68 Teil 2-20
+ Mikroimpedanzmeßgerät EMT 328
+ Korrosionsprüfkammer K350 + TOX GAS Monitor 7100 (TZO Leipzig)
+ Lötbad gemäß DIN IEC Teil 2-20
DIMENSIONS IN MILLIMETERS - VALUES FOR INCHES IN BRACKETS - TECHNICAL DATA SUBJECT TO CHANGE
Value after 250 contact durability tests and 21 days corrosive gas)
contact durability tests)
to flowing mixed gases in accordance with DIN EN 60068-2-60, test Ke,
Method 4)
250 Steckzyklen und 21 Tagen Schadgas)
strömendes Mischgas nach DIN EN 60068-2-60, Prüfung Ke, Methode 4)
FCT führt eine Nickel-Phosphor-Gold Oberfläche (min 0,1 µm Au über
2 - 4 µm chemisches NiP) ein, die im Vergleich zu herkömmlichen Beschich-
tungen bessere Eigenschaften aufweist.
Steckverbinder und Kontakte mit Nickel-Phosphor-Gold Oberfläche sind ent-
sprechend den Anforderungen der DIN 41626, Teil 1 und DIN 41652 Teil 2
getestet. Ein entsprechender Testbericht ist auf Anfrage erhältlich von:
Sales Team FCT
sales@fctgroup.com
+ hohe Abriebsbeständigkeit
+ sehr gute Korrosionsbeständigkeit
+ niedriger Kontaktwiderstand, sehr gute Kontakteigenschaften
+ hervorragende Lötbarkeit
+ gleichmäßige Schichtdicke
+ RoHS konform
+ auf Wunsch non-magnetisch
Storage of the test object during the mixed gas exposure
Lagerung der Testobjektes während der Mischgasexposition
ML 12/2008
9

Related parts for F2W2SC-1002