ABA.00.250.NTL LEMO, ABA.00.250.NTL Datasheet - Page 44

RF Connectors ADAPTOR SOCKET TO BNC PLUG

ABA.00.250.NTL

Manufacturer Part Number
ABA.00.250.NTL
Description
RF Connectors ADAPTOR SOCKET TO BNC PLUG
Manufacturer
LEMO
Datasheet

Specifications of ABA.00.250.NTL

Body Style
Adapter
Connector Type
Adapter
Features
IP rating 50
Housing Material
Brass
Length
28.5 mm
Mounting Angle
Straight
Operating Temperature Range
- 55 C to + 260 C
Rf Series
Between Series
Product
Adapters
Gender
Male, Female
Polarity
Normal
Shell Plating
Nickel
Impedance
50 Ohms
Termination Style
Quick Connect
Convert From
LEMO Socket
Convert To
BNC Plug
Side 1 Rf Series
Lemo 00
Side 2 Rf Series
BNC
Side 2 Gender
Plug (Male)
Adapter Style
Straight
Body Material
Brass
Side 1 Gender
Plug (Male)
Side 1 Polarity
Normal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Terminating of elbow plugs (90°) with cable collet (solder contact)
42
®
L ± 0.2
Solder
T ± 0.2
S ± 0.2
®
1
2
3
1.
2.
2.1 Place the crimp ferrule ➀ and
2.2 Slide the assembly into
2.3 Place the insulating sleeve ➃
2.4 Close the access hole with
Note: these terminating instruc-
tions apply to the following
models:
M6 = FLA
1-2-3-4-8
4
Cable
group
Cable preparation
First place the bend relief
(if to be used) on the cable.
Strip the cable according to
dimensions below.
Cable terminating
collet ➁ on the cable. Fold
back the shield braid onto
the conical part of the collet,
and trim to outer edge of the
collet.
the connector shell ➂
and tighten the collet nut ➀
using the appropriate tool
to a torque of 0.25 Nm
(see “Tooling” on page 35,
36 and 37). Check that
the cable conductor rests
in the contact slot, solder
the conductor through
the hole.
over the soldered contact.
the flat screw ➄.
Push the bend relief (if used)
onto the collet nut ➀.
5
T
1
M6
3.5
S
6.5
L
Solder
L
T
0.2
M6
S
0.2
0.2
and cable crimp (solder contact)
1
2
1.
2.
2.1 Place the cable crimp ferrule
2.2 Slide the cable into the con-
2.3 Place the insulating sleeve ➂
2.4 Close the connector hole
Note: these terminating instruc-
tions apply to the following
models:
M7 = FLS, FLV
1-2-3-4-8
3
Cable
group
Cable preparation
First place the bend relief
(if to be used) on the cable.
Strip the cable according to
dimensions below.
Cable terminating
➀ on the cable and widen
the braiding.
nector shell ➁. Check that
cable conductor rests in the
contact slot, tin solder the
conductor through the hole.
Slide the crimp ferrule ➀ over
the braiding until it reaches
the connector shell ➁. Crimp
with the LEMO crimp tool
using the hexagonal opening
(see “Tooling” on page 37).
over the soldered contact.
with the flat screw ➃.
Push the bend relief (if used)
onto the crimping tube ➀.
6-7
4
T
1
3
www.lemo.com
M7
4.5
4.5
S
M7
11
L
9

Related parts for ABA.00.250.NTL