2967617 Phoenix Contact, 2967617 Datasheet - Page 2

no-image

2967617

Manufacturer Part Number
2967617
Description
General Purpose / Industrial Relays PLC-RSC-12DC/21 HC RELAY PN 651-2961309
Manufacturer
Phoenix Contact
Series
-r
Datasheets

Specifications of 2967617

Contact Form
SPDT
Coil Voltage
12 V
Contact Rating
6 A at 250 V
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
140 W
Contact Material
Silver Tin Oxide
Coil Current
15.3 mA
Brand/series
PLC-RSC/RSP
Function
PLC
Phoenix Part Number
PLC-RSC-12DC/21 HC
Relay Type
General Purpose
Contact Rating (current)
10A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Non Latching
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Operate Time
8ms
Release Time
10ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-40°C ~ 60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ordering Data
Technical Data
100221_03_en
Description
PLC INTERFACE With Screw Connection
PLC INTERFACE with SPDT relay,
high-current version, comprising PLC-BSC-...
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for assembly
on
PLC INTERFACE With Spring-Cage Connection
PLC INTERFACE with SPDT relay,
high-current version, comprising PLC-BSC-...
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for assembly
on
Accessories
Description
Insulating plate
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.
Input Data
Nominal input voltage U
Permissible range (with reference to U
Typical input current at U
Typical response time at U
Typical release time at U
Input circuit
DC
AC/DC
3
3
1
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
.
.
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for
potential bridging) and for safe isolation between adjacent modules.
N
N
N
1
N
N
)
Yellow LED, protection against polarity reversal, free-wheeling diode
Yellow LED, bridge rectifier
...12DC... ...24DC... ...24UC... ...48DC... ...60DC... ...120UC... ...230UC...
12 V DC
33 mA
230 V AC/220 V DC
230 V AC/220 V DC
120 V AC/110 V DC
120 V AC/110 V DC
24 V AC/DC
24 V AC/DC
24 V DC
12 V DC
24 V DC
48 V DC
60 V DC
12 V DC
24 V DC
48 V DC
60 V DC
18 mA
1
1
Type
PLC-RSC- 12DC/21HC
PLC-RSC- 24DC/21HC
PLC-RSC- 24UC/21HC
PLC-RSC- 48DC/21HC
PLC-RSC- 60DC/21HC
PLC-RSC-120UC/21HC
PLC-RSC-230UC/21HC
PLC-RSP- 12DC/21HC
PLC-RSP- 24DC/21HC
PLC-RSP- 24UC/21HC
PLC-RSP- 48DC/21HC
PLC-RSP- 60DC/21HC
PLC-RSP-120UC/21HC
PLC-RSP-230UC/21HC
Type
PLC-ATP BK
24 V AC/DC
See "Operating Voltage Ranges" on page 4
17.5 mA
8 ms
48 V DC
20 mA
10 ms
60 V DC
10 mA
Order No.
2967617
2967620
2967633
2967646
2967659
2967662
2967675
2912264
2912277
2912280
2912293
2912303
2912316
2912329
Order No.
2966841
120 V AC/
110 V DC
4.5 mA/
4.2 mA
PHOENIX CONTACT
PLC-R…21HC
7 ms
Pcs./Pck.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Pcs./Pck.
25
230 V AC/
220 V DC
4.5 mA/
4.3 mA
2