MY4-02-AC110-120 Omron, MY4-02-AC110-120 Datasheet - Page 5

General Purpose / Industrial Relays 4PDT 5A 110/120VAC

MY4-02-AC110-120

Manufacturer Part Number
MY4-02-AC110-120
Description
General Purpose / Industrial Relays 4PDT 5A 110/120VAC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY4-02-AC110-120

Contact Form
4PDT
Coil Voltage
110 VAC / 120 VAC
Contact Rating
5 A
Contact Termination
Solder Terminal
Mounting Style
Socket
Power Consumption
0.9 VA to 1.1 VA
Contact Material
Silver with Gold Flash
Coil Current
8.4 mA, 9.2 mA
Coil Type
Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
02 110/120AC MY4 MY402110120AC,
MY
Non-latching
Latching
Note: Data shown are of initial value.
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
CHARACTERISTICS
Mechanically
Under rated load
Single contact type
Bifurcated contact type
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Mechanically
Electrically
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
50 m
20 ms max.
20 ms max.
18,000 operations/hour
1,800 operations/hour
100 M
Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
Sealed:
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
Unsealed: -55 to 70 C (-67 to 158 F)
Sealed:
Hermetically sealed: 25 to 60 C (77 to 140 F)
35% to 85% RH
Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
See “Characteristic Data”
Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
50 m
AC: 30 ms max.; DC: 15 ms max.
AC: 30 ms max.; DC: 15 ms max.
18,000 operations/hour
1,800 operations/hour
100 M
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
-55 to 70 C (-67 to 158 F)
45% to 85% RH
100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 30 g (1.06 oz)
max.
max.
2
2
min. (at 500 VDC)
min. (at 500 VDC)
(approx. 20 G)
(approx. 20 G)
2
2
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
-55 to 60 C (-67 to 140 F)
(approx. 100 G)
(approx. 100 G)
MY
5