G6DS-1A-DC12 Omron, G6DS-1A-DC12 Datasheet - Page 2

General Purpose / Industrial Relays SPST-NO 5A 12VDC Sealed

G6DS-1A-DC12

Manufacturer Part Number
G6DS-1A-DC12
Description
General Purpose / Industrial Relays SPST-NO 5A 12VDC Sealed
Manufacturer
Omron
Series
G6DSr
Datasheet

Specifications of G6DS-1A-DC12

Coil Resistance
800 Ohms
Contact Form
SPST - NO
Coil Voltage
12 VDC
Contact Rating
5 A at 250 VAC
Contact Termination
Solder Leads
Mounting Style
PCB
Power Consumption
180 mW
Coil Current
5 A
Coil Type
Non-Latching
Relay Type
Miniature
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
12DC, G6DS-1A G6DS1A12DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6DS-1A-DC12V
Quantity:
12 000
G6DS
Note:
Note:
Note:
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
(See note.)
Contact resistance (See note 1.)
Operate time
Release time
Insulation resistance (See note 2.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Coil Ratings
Contact Ratings
Characteristics
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. “Max. voltage” refers to the maximum voltage that can be applied to the relay coil. It is not the maximum voltage that can be
P level: λ 60 = 0.1 × 10
The data shown above are initial values.
1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
2. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
applied continuously.
Item
Item
-6
operation
5 VDC
36 mA
139 Ω
70% max. of rated voltage
5% min. of rated voltage
160% of rated voltage (at 23 ° C)
Approx. 180 mW
5 A at 250 VAC, 5 A at 30 VDC
5 A
250 VAC, 30 VDC
5 A
1,250 VA, 150 W
5 mA at 24 VDC
100 m Ω max.
10 ms max.
5 ms max.
1,000 M Ω min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
6,000 V (1.2 x 50 µs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 150 m/s
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
Operating: − 40°C to 85°C (with no icing)
Operating: 5% to 85%
Approx. 2.3 g
Resistive load (cos φ =1)
100,000 operations min. (at 1,800 operations/hr) for standard type.
80,000 operations min. (at 1,800 operations/hr) for high-sensitivity type. (at 23°C)
12 VDC
15 mA
800 Ω
Standard
2
2
(standard type). 130 m/s
24 VDC
7.5 mA
3,200 Ω
2
5 VDC
24 mA
208 Ω
Approx. 120 mW
2 A at 250 VAC, 2 A at 30 VDC
(high-sensitivity type)
Inductive load (cos φ =0.4, L/R=7 ms)
High-sensitivity
12 VDC
10 mA
1,200 Ω
24 VDC
5 mA
4,800 Ω
G6DS