2967662 Phoenix Contact, 2967662 Datasheet - Page 2

no-image

2967662

Manufacturer Part Number
2967662
Description
General Purpose / Industrial Relays PLC-RSC-120UC/21 HC RELAY PN 651-2961338
Manufacturer
Phoenix Contact
Series
296r
Datasheets

Specifications of 2967662

Contact Form
SPDT
Coil Voltage
120 V
Contact Rating
4.5 mA
Contact Termination
Plug-In
Mounting Style
PCB
Contact Material
Silver Nickel
Coil Type
Non-Latching
Brand/series
PLC-RSC/RSP
Current, Rating
10 A
Dimensions
80 mm L x 14 mm W x 94 mm H
Function
PLC
Material, Contact
AgNi
Phoenix Part Number
PLC-RSC-120UC/21 HC
Power, Rating
50 W
Relay Type
Electro Mechanical
Standards
cULus, UL, RoHS
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Screw
Voltage, Control
120 VAC
Voltage, Rating
250 VAC/VDC
Contact Rating (current)
10A
Switching Voltage
250VAC, 250VDC - Max
Coil Current
4.5mA
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Operate Time
7ms
Release Time
10ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-40°C ~ 60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PLC-RSC-120UC/21HC
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2967662
PHOENIX CONTACT GmbH & Co. KG
Typical response time
Typical release time
Operating voltage display
Name of protection
Protective circuit/component
Contact side
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Maximum inrush current
Min. switching current
Limiting continuous current
Interrupting rating (ohmic load) max.
Interrupting rating (ohmic load) max. bridged
General data
Length
Height
Width
Test voltage relay winding/relay contact
Ambient temperature (operation)
Ambient temperature (storage/transport)
Operating mode
Service life mechanical
Order No.: 2967662
7 ms
10 ms
Yellow LED
Bridge rectifier
Bridge rectifier
Single contact, 1-PDT
AgNi
250 V AC/DC (The separating plate PLC-ATP should be installed
for voltages larger than 250 V (L1, L2, L3) between identical
terminal blocks in adjacent modules. Potential bridging is then
carried out with FBST 8-PLC... or ...FBST 500...)
12 V AC/DC
30 A (300 ms)
100 mA
10 A
6 A (value applies to connections 12. If connections 12 are
bridged, the normal value applies.)
240 W (for 24 V DC)
58 W (for 48 V DC)
48 W (for 60 V DC)
50 W (for 110 V DC)
80 W (for 220 V DC)
2500 VA (for 250 V AC)
144 W (for 24 V DC. Value applies to connections 12. If
connections 12 are bridged, the normal value applies.)
1500 VA (for 250 V AC. Value applies to connections 12. If
connections 12 are bridged, the normal value applies.)
80 mm
94 mm
14 mm
4 kV AC (50 Hz, 1 min)
-25 °C ... 60 °C
-40 °C ... 85 °C
100% operating factor
3 x 10
7
cycles
May 31, 2008
Page 2 / 6