2 Form A, 2 Form B
Coil Voltage
24 VDC
Contact Rating
6 A at 250 VAC, 6 A at 30 VDC
Coil Termination
Solder Pin
Contact Termination
Solder Pin
Mounting Style
Through Hole
Power Consumption
500 mW
Contact Material
Gold Flashed Silver Alloy
Coil Current
20.8 mA
Coil Resistance
1.152 K Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SF Double contact type
THE OPERATION OF SF RELAYS (when contacts are welded)
SF relays work to maintain a normal operating state even when the contact welding occur by overloading or short-circuit
currents. It is easy to make weld detection circuits and safety circuits in the design to ensure safety even if contacts weld.
1) 2 Form A 2 Form B type
If the form “b” contact (No. 1 and 3) welds, the armature becomes non-operational, the contact gaps at the three form “a” contacts are
maintained at greater than 0.5 mm
When the form “a” contacts (No. 2 or 4) weld, the armature remains in a non-returned state and the contact gap at the two form “b”
contact is maintained at greater than 0.5 mm
No.4
No.3
No.4
No.3
No.4
No.3
Terminal No.
Contact No.
Contact Operation Table
Form “b” Contact Weld
Form “a” Contact Weld
Non-energized
11–12
No.1
Energized
No.2
7–8
No.3
5–6
9–10
No.4
No.1
No.2
No.1
No.2
No.1
No.2
.020
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
inch. Reliable isolation is thus ensured.
.020
The table below shows the state of the other contacts when the current through
the welded form “a” contact is 0 V and the rated voltage is applied through the
form “b” contact.
* Contact gaps are shown at the initial state.
If the contacts change state owing to loading/breaking
it is necessary to check the actual loading.
terminal
Welded
No.4
No.3
No.4
No.3
Non-energized (when No. 2 contact is welded)
No.
Energized (when No. 1 contact is welded)
inch. Reliable isolation is thus ensured.
1
2
3
4
>0.5
>0.5
1
State of other contacts
>0.5
>0.5
2
>0.5
>0.5
3
No.1
No.2
No.1
No.2
>0.5
>0.5
4
Example: If the No. 1 contact welds
Each of the three form “a” contacts (No. 2 and 4)
maintain a gap of greater than 0.5 mm
Example: If the No. 2 contact welds.
The two form “b” contact (No. 1 or 3) maintains a gap of
greater than 0.5 mm
>0.5: contact gap is kept at
Empty cells: either closed or open
min. 0.5 mm
.020
.020 inch
inch.
.020
inch.