D4NS-1AF Omron, D4NS-1AF Datasheet

Basic / Snap Action / Limit Switches Plastic NC1NO type Interlock

D4NS-1AF

Manufacturer Part Number
D4NS-1AF
Description
Basic / Snap Action / Limit Switches Plastic NC1NO type Interlock
Manufacturer
Omron
Type
Safety Door Key Switchr
Datasheets

Specifications of D4NS-1AF

Contact Form
1 NC / 1 NO
Contact Rating
10 Amps at 120 VoltsAC, 240 VoltsAC
Actuator
Key
Contact Voltage Ac Max
400V
Contact Voltage Dc Max
250V
Contact Current Ac Max
6A
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60947-5-1, IEC 947-5-1, EN1088, EN50047, UL508, CSA C22.2
Key Type
Key
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Multi-contact, Labor-saving, Environment-
friendly, Next-generation Safety-door Switch
• Lineup includes three contact models with 2NC/1NC and 3NC
• M12-connector models are available, saving on labor and sim-
• Standardized gold-clad contacts provide high contact reliability.
• Applicable to both standard loads and micro loads.
• Free of lead, cadmium, and hexavalent chrome, reducing the
Model Number Structure
Switch
1. Conduit/Connector size
2. Built-in Switch
3. Head Mounting Direction
Note: An order for the head part or the switch part alone cannot be
D4NS-@@@
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC.
plifying replacement.
burden on the environment.
Safety-door Switch
D4NS
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT compatible (2-conduit model with M20 conduit size
8: M20 (2-conduit)
9: M12 connector (1-conduit)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact)
F: 2NC/1NO (MBB contact)
F: Four mounting directions possible (Front-side mounting at ship-
Model Number Legend
includes an M20-to-1/2-14NPT conversion adapter)
ping)
accepted. The Operation Key is sold separately.
1 2 3
Operation Key
1. Operation Key Type
D4DS-K@
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
5: Adjustable mounting (Horizontal/ Vertical)
1
Safety-door Switch
D4NS
1

Related parts for D4NS-1AF

D4NS-1AF Summary of contents

Page 1

... F: Four mounting directions possible (Front-side mounting at ship- ping) Note: An order for the head part or the switch part alone cannot be accepted. The Operation Key is sold separately. Operation Key D4DS- Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 5: Adjustable mounting (Horizontal/ Vertical) Safety-door Switch D4NS 1 ...

Page 2

... M20 1NC/1NO Pg13.5 G1/2 M20, includes M20-to-1/2-14NPT conversion adapter M20 2NC/1NO Pg13.5 G1/2 M20, includes M20-to-1/2-14NPT conversion adapter M20 1NC/1NO M12 connector 2NC 1NC/1NO Model D4NS-1AF D4NS-2AF D4NS-3AF D4NS-4AF D4NS-1BF D4NS-2BF D4NS-3BF D4NS-4BF D4NS-1CF D4NS-2CF D4NS-3CF D4NS-4CF D4NS-1DF D4NS-2DF D4NS-3DF D4NS-4DF ...

Page 3

... This fuse is not built into the Switch. UL/CSA (UL508, CSA C22.2 No. 14) A300 Rated voltage 120 VAC 240 VAC File No. Under application Utilization AC-15 category ) 240 V 250 V e Carry current Current Volt-amperes Make Break Make 7,200 VA 720 D4NS Safety-door Switch DC-13 Break 3 ...

Page 4

... The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi- cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal- functioning may occur. ...

Page 5

... D4NS-@C@, D4NS-@D@, D4NS-@F@ Head The head can be mounted in four directions. Sealing properties The switch casing ensures IP67 (except the keyhole, which ensures IP00). Use the D4NS in places where the keyhole is free from oil, water, and metal chips. Terminal 11 Terminal 12 Terminal 21 Terminal 31 (33) ...

Page 6

... Two, 4 depth: 5 2.15±0.05R mounting holes M12 1 22 14.2 0 D4NS-1@F Operating D4NS-2@F characteristics D4NS-3@F D4NS-4@F Key insertion force 15 N max. Key extraction force 30 N max. Pretravel (PT) Total travel (TT) +0.15 Direct opening force 60 N min. dia. holes * 0 Direct opening stroke 10 mm min. * ...

Page 7

... Permissible difference in center lines between the Operation Key and key hole Black 6.3 20 Black D4NS-1@F + D4DS- 42.5 Red Key insertion face (30.6) Black (30. 42.5 Key insertion face 51.9 to 54.4 Key insertion face Red (30.6) Black Horizontal key insertion radius R 50 (30.6) 51 ...

Page 8

... Do not use metal connector or conduit with this switch. The broken conduit hole may cause electrical shock hazard. Precautions for Safe Use • Be careful not to drop your D4NS, or the switch will not fully exhibit its ability. • Do not disassemble or remodel your D4NS in any case, or the D4NS will not operate normally. • ...

Page 9

... Make sure, however, that the socket connector is tightened securely, otherwise the rated degree of protection of the D4NS may not be maintained. Furthermore, the socket connector may be loosened by vibration. 8. Conduit opening ...

Page 10

... Cap 47 14.2 30 +0.15 Two, 4 dia. holes 0 depth: 5 D4DS product Recommended substitute product D4NS-1AF D4NS-2AF D4NS-3AF D4NS-5AF D4NS-6AF D4NS-1BF D4NS-2BF D4NS-3BF D4NS-5BF D4NS-6BF Replacement products (1-conduit D4NS) Head cap 7.5 30.2 30.6 15.3 15.5 4.4 41 33.5 2 ...

Page 11

... When transferring devices and equipment, be sure to keep one copy of the Operating Manual and pack another copy with the device or equipment so the person receiving it will have no problem operating it. • Related international standards: ISO/DIS 12100 "Basic concepts, general principles for design" IEC 61508 "Functional safety of electrical/electronic/programmable electronic safety-related systems." !WARNING Safety-door Switch D4NS 11 ...

Page 12

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Related keywords