Si8512-C-IS Silicon Laboratories Inc, Si8512-C-IS Datasheet - Page 21

Board Mount Current Sensors 10A DUAL OUTPUT 5kV

Si8512-C-IS

Manufacturer Part Number
Si8512-C-IS
Description
Board Mount Current Sensors 10A DUAL OUTPUT 5kV
Manufacturer
Silicon Laboratories Inc
Type
AC Current Sensorr
Series
-r
Datasheet

Specifications of Si8512-C-IS

Current Rating
10 A
Supply Voltage
2.7 V to 5.5 V
Frequency Range
50 KHz to 1 MHz
Operating Temperature
- 40 C to + 125 C
Accuracy
5 %
Current - Sensing
10A
Sensitivity
196mV/A
Current - Supply
4mA
Sensor Type
Closed Loop
Voltage - Supply
2.7 V ~ 5.5 V
Output
Configurable
Frequency
50kHz ~ 1MHz
Response Time
-
Polarization
Unidirectional
Package / Case
20-SOIC (0.295", 7.50mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1425 - BOARD EVAL CURRENT SENSOR 10A
3.4. Single-Phase Buck Converter Example
In this example, the Si850x is configured to operate in a single-phase synchronous buck converter (Figure 17).
This converter has a PWM frequency of 1 MHz and a maximum duty cycle of 80%.
This is an example of a half-wave application that can be addressed with Single-Ended output mode. The PWM
period is calculated to be 1/10
maximum duty cycle (R
In this example, the current measurement is made when the buck switch is on; so, PH2 is chosen as the reset
signal by connecting PH2 to R1 and grounding R2 and R3. The PH2 signal can be obtained at the input of the
driver external to the PWM controller or the output of the controller's internal driver (through a resistor divider if the
driver output swings beyond the device VDD range).
0.1 µF
C1
PH2
TRST
1 µF
C2
R
TRST
= 20 k).
Figure 17. Si850x Single-Phase Buck Converter
PH1
VDD1
TRST
–6
R2
R1
= 1.0 µs, and the worst-case value, t
VDD
VDD2
Si850x
IOUT
VIN
IIN
Preliminary Rev. 0.21
Q1
L1
Q2
GND2
GND1
GND3
OUT
C3
VOUT
Si850x State
R
, is 0.2 x 1.0 x 10
Current
PH2
2 Vpp
RESET
100 ns
PWM
I = 0
MEASURE
–6
I > 0
= 200 ns at 80%
Si85xx
21