Si1141-A10-GM Silicon Laboratories Inc, Si1141-A10-GM Datasheet - Page 54

Proximity Sensors IC INTERFACE

Si1141-A10-GM

Manufacturer Part Number
Si1141-A10-GM
Description
Proximity Sensors IC INTERFACE
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of Si1141-A10-GM

Maximum Operating Temperature
+ 85 C
Supply Voltage
3.3 V
Supply Current
5.6 mA to 360 mA
Operating Supply Voltage
1.8 V to 3.6 V
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Current Rating
359 mA
Voltage Rating
4 V
Sensing Distance
1 m
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Si1141-A10-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
Si1141-A10-GMR
Quantity:
2 500
Company:
Part Number:
Si1141-A10-GMR
Quantity:
2 500
Si1141/42/43
PS1_ADCMUX @ 0x07
Reset value = 0000 0011
54
Name
Type
Bit
7:0
Bit
PS1_ADCMUX[7:0] Selects ADC Input for PS1 Measurement.
7
Name
6
The following selections are valid when PS_ADC_MODE = 1 (default). This set-
ting is for normal Proximity Detection function.
0x03: Large IR Photodiode
0x00: Small IR Photodiode
In addition, the following selections are valid for PS_ADC_MODE = 0. With this
setting, irLED drives are disabled and the PS channels are no longer operating in
normal Proximity Detection function. The results have no reference and the refer-
ences needs to be measured in a separate measurement.
0x02: Visible Photodiode
A separate 'No Photodiode' measurement should be subtracted from this reading.
Note that the result is a negative value. The result should therefore be negated to
arrive at the Ambient Visible Light reading.
0x03: Large IR Photodiode
A separate “No Photodiode” measurement should be subtracted to arrive at
Ambient IR reading.
0x00: Small IR Photodiode
A separate “No Photodiode” measurement should be subtracted to arrive at
Ambient IR reading.
0x06: No Photodiode
This is typically used as reference for reading ambient IR or visible light.
0x25: GND voltage
This is typically used as the reference for electrical measurements.
0x65: Temperature
(Should be used only for relative temperature measurement. Absolute Tempera-
ture not guaranteed) A separate GND measurement should be subtracted from
this reading.
0x75: V
A separate GND measurement is needed to make the measurement meaningful.
DD
5
voltage
PS1_ADCMUX[7:0]
Rev. 1.1
4
RW
Function
3
2
1
0

Related parts for Si1141-A10-GM