E2KX15MY1 Omron, E2KX15MY1 Datasheet - Page 5

Proximity Sensors 2 WIRE PROX SENSOR

E2KX15MY1

Manufacturer Part Number
E2KX15MY1
Description
Proximity Sensors 2 WIRE PROX SENSOR
Manufacturer
Omron
Type
Capacitiver
Series
E2K-Cr
Datasheet

Specifications of E2KX15MY1

Maximum Operating Temperature
+ 55 C
Supply Voltage
90 V to 250 V
Supply Current
15 mA
Operating Supply Voltage
90 V to 250 V
Mounting Style
Cable
Minimum Operating Temperature
- 10 C
Maximum Output Current
200 mA
Features
High visibility indicator
Sensing Distance
15 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
● Design
Ambient Environment
The Sensor may malfunction if subjected to water, oil, chemicals, or
condensation by falsely detecting these as sensing objects.
The E2K-X15M is highly sensitive to inductive objects and can thus
be affected even by small quantities of water drops.
Influence of Surrounding Objects
If the Sensor is embedded in metal, maintain at least the following
distances between the Sensor and the metal. The Sensor is also
affected by other materials, such as resins. Separate the Sensor from
other materials by the same distance as for metal.
* Be sure to ground the metal object, otherwise Sensor operation will not be
Influence of Surrounding Metal
If a mounting bracket is used, be sure that at least the following
distances are maintained.
Influence of Surrounding Metal
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Mutual Interference
Model
E2K-X4M
E2K-X8M
E2K-X15M
Model
E2K-X4M
E2K-X8M
E2K-X15M
Model
E2K-X4M
E2K-X8M
E2K-X15M
stable.
(Unit: mm)
Dimension
Dimension
Dimension
Precautions for Correct Use
Be sure to ground.
l
A
150
300
20
10
20
10
80
G
A
l
*
WARNING
(Unit: mm)
110
200
50
30
70
d
H
B
d dia.
Metal object
(Unit: mm)
B
12
25
m
8
H
60
n
G
n
m
Sensing Objects
The maximum sensing distance will decrease if the sensing object is
a non-grounded metal object or dielectric object.
Effects of a High-frequency Electromagnetic Field
The E2K-X may malfunction if there is an ultrasonic washer, high-
frequency generator, transceiver, or inverter nearby.
For major measures, refer to Noise of Warranty and Limitations of
Liability for Photoelectric Sensors.
Mounting
Do not tighten the nut with excessive force. Always use washers when
tightening the nuts and do not exceed the torque in the following table.
Note: A special tightening tool is provided with the E2K-X4M@@. Always use
● Miscellaneous
Organic Solvents
The Sensor has a case made of heat-resistant ABS resin. Be sure
that the case is free from organic solvents or solutions containing
organic solvents.
• Sensing Object Material
• There are objects that cannot be detected indirectly. Therefore, be
Model
E2K-X4M
E2K-X8M
E2K-X15M
The E2K-X can detect almost any type of object. The sensing
distance of the E2K-X, however, will vary with the electrical
characteristics of the object, such as the conductance and
inductance of the object, and the water content and capacity of the
object. The maximum sensing distance of the E2K-X will be
obtained if the object is made of grounded metal.
sure to test the E2K-X in a trial operation with the objects before
using the E2K-X in actual applications.
this tool to tighten the nuts.
0.78 N·m
Torque