E2K-X15ME1 Omron, E2K-X15ME1 Datasheet
E2K-X15ME1
Specifications of E2K-X15ME1
Available stocks
Related parts for E2K-X15ME1
E2K-X15ME1 Summary of contents
Page 1
... Unshielded M18 8 mm M30 Accessories (Order Separately) Mounting Brackets @ Refer to Y92 for details. Output configuration DC 3-wire, NPN AC 2-wire DC 3-wire, NPN AC 2-wire DC 3-wire, NPN 2-wire CSM_E2K-X_DS_E_3_1 Model Operation mode NO NC E2K-X4ME1 2M E2K-X4ME2 2M E2K-X4MY1 2M E2K-X4MY2 2M E2K-X8ME1 2M E2K-X8ME2 2M E2K-X8MY1 2M E2K-X8MY2 2M E2K-X15ME1 2M E2K-X15ME2 2M E2K-X15MY1 2M E2K-X15MY2 2M 1 ...
Page 2
... E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±20% (average value) can be used. E2K-X8ME@, E2K-X8MY ±10 5.6 mm Refer to the timing charts under I/O Circuit Diagrams on page 4 for details times each and Z directions Approx. 145 g Instruction manual E2K-X E2K-X15ME@, E2K-X15MY ±10 Operating/Storage: −10 to 55°C (with no icing or condensation) Approx. 205 g 2 ...
Page 3
... Grounded metal plate 50 × 50 × E2K-X8M 6 4 E2K-X4M 2 0 −5 −20 −15 −10 − E2K-X4M Sensing Distance Y (mm) E2K-X8M Sensing Head E2K-X15M Sensing Head Influence of Sensing Object Size and Material E2K-X4M 5 d × Grounded metal 4 3 Non-grounded metal 2 1 Glass Phenol ...
Page 4
... DC 3-Wire Models Operation Model mode Sensing object Load (between brown E2K-X4ME1 and black leads) NO E2K-X8ME1 Output voltage (between E2K-X15ME1 black and blue leads) Detection indicator (red) Sensing object Load (between brown E2K-X4ME2 and black leads) NC E2K-X8ME2 Output voltage (between E2K-X15ME2 black and blue leads) ...
Page 5
... The maximum sensing distance of the E2K-X will be obtained if the object is made of grounded metal. • There are objects that cannot be detected indirectly. Therefore, be sure to test the E2K trial operation with the objects before using the E2K-X in actual applications. Effects of a High-frequency Electromagnetic Field The E2K-X may malfunction if there is an ultrasonic washer, high- frequency generator, transceiver, or inverter nearby ...
Page 6
... Mounting Hole Dimensions F Indicator *2 *1 M30 × 1.5 E2K-X (Unit: mm Indicator * 16.6 dia. *1 M18 × 1 Two clamping nuts Two washers 2 , Insulator diameter: 1.9 mm Insulator diameter: 1.9 mm), Model F (mm) E2K-X4ME@ +0.5 12.5 dia. 0 E2K-X4MY@ E2K-X8ME@ +0.5 18.5 dia. 0 E2K-X8MY@ E2K-X15ME@ +0.5 30.5 dia. E2K-X15MY ...
Page 7
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...