E2E2-X5MC1 Omron, E2E2-X5MC1 Datasheet - Page 11

Proximity Sensors Long 5 mm Sens NPN M12 Conn

E2E2-X5MC1

Manufacturer Part Number
E2E2-X5MC1
Description
Proximity Sensors Long 5 mm Sens NPN M12 Conn
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Series
E2E2r
Datasheets

Specifications of E2E2-X5MC1

Maximum Operating Temperature
+ 70 C
Supply Voltage
24 V
Operating Supply Voltage
10 V to 30 V
Minimum Operating Temperature
- 25 C
Maximum Output Current
100 mA
Barrel Size
M12
Features
High visibility indicator
Sensing Distance
5 mm
Rohs Compliant
Yes
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
400Hz
Material - Body
Nickel-Plated Brass
Shielding
Unshielded
Voltage - Supply
10 V ~ 55 V
Output Type
NPN-NO
Terminal Type
3-Wire
Package / Case
Cylinder, Threaded - M12
Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Dc
12V To 24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dimensions
E2E2-X10D@/E2E2-X10C@/E2E2-X10Y@
Mounting Hole Dimensions
Shielded
E2E2-X3D@/E2E2-X2C@/E2E2-X2Y@
E2E2-X7D@/E2E2-X5C@/E2E2-X5Y@
21 dia.
29 dia.
17
42 dia.
24
36
Note 1. Two clamping nuts and one toothed washer are provided with each Sensors.
2. The model number is laser-marked on the cable section and milled section.
M12 × 1
M18 × 1
M30 × 1.5
*1. 4-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
*1. 6-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
*1. 6-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
(Conductor cross section: 0.3 mm
Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.3 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
(Conductor cross section: 0.5 mm
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
4
(Conductor cross section: 0.5 mm
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
4
http://www.ia.omron.com/
5
Toothed washer
Two clamping nuts
Toothed washer
Two clamping nuts
55
Toothed washer
60
Two clamping nuts
60
65
65
70
In the interest of product improvement, specifications are subject to change without notice.
10
10
2
2
, Insulator diameter: 1.3 mm),
, Insulator diameter: 1.3 mm),
2
2
, Insulator diameter: 1.9 mm),
, Insulator diameter: 1.9 mm),
10
9
2
2
Indicators *2
, Insulator diameter: 1.9 mm),
, Insulator diameter: 1.9 mm),
12
F
Indicators *2
12
Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
Indicators *2
*1
*1
*1
Dimension
F (mm)
E2E2-X20MD@/E2E2-X18MC@/E2E2-X18MY@
Unshielded
E2E2-X8MD@/E2E2-X5MC@/E2E2-X5MY@
E2E2-X14MD@/E2E2-X10MC@/E2E2-X10MY@
21 dia.
42 dia.
29 dia.
17
36
24
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
12.5
9 dia.
26.8 dia.
14.8 dia.
M12
*1. 4-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
+0.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
*1. 6-dia. vinyl-insulated round cable with 2 conductors
*2. D Models: Operation indicator (red) and setting indicator (green),
0
(Conductor cross section: 0.3 mm
Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.3 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
(Conductor cross section: 0.5 mm
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
(Conductor cross section: 0.5 mm
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
C/Y Models: Operation indicator (red)
dia.
M30 × 1.5
M12 × 1
7
M18 × 1
13
10
18.5
4
5
4
M18
+0.5
0
Toothed washer
55
60
Two clamping nuts
Toothed washer
Two clamping nuts
60
65
dia.
65
Toothed washer
Two clamping nuts
70
30.5
10
10
2
2
2
2
, Insulator diameter: 1.3 mm),
, Insulator diameter: 1.3 mm),
, Insulator diameter: 1.9 mm),
, Insulator diameter: 1.9 mm),
2
2
, Insulator diameter: 1.9 mm),
, Insulator diameter: 1.9 mm),
M30
+0.5
0
10
12
dia.
Indicators *2
Indicators *2
9
12
Indicators *2
E2E2
(Unit: mm)
*1
*1
*1
11

Related parts for E2E2-X5MC1