PS-1223 Power-Sonic, PS-1223 Datasheet

no-image

PS-1223

Manufacturer Part Number
PS-1223
Description
Sealed Lead Acid Battery 12V 2.3AH 115mA PRESSURE CONTACTS
Manufacturer
Power-Sonic
Type
Sealed Lead Acid Batteriesr
Datasheet

Specifications of PS-1223

Output Voltage
12 V
Chemistry
Lead Acid
Rechargeable/non-rechargeable
Rechargeable
Battery Capacity
2.3 Ah
Capacity
2.3 Ah
Termination Style
Flat
Brand/series
PS Series
Chemical System
Lead Acid
Classification
Rechargeable
Dimensions
7.17"L×0.94"W×2.4"H
Material, Jacket
Non-Conductive ABS Plastic
Primary Type
Rechargeable
Size
Rectangular
Temperature, Operating
-20 to +50 °C
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-40 °C
Termination
Pressure Contact
Voltage, Nominal
12 VDC
Voltage, Rating
12 V
Weight
1.7 lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
To ensure safe and effi cient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.
PS-1223
Terminals
Physical Dimensions: in (mm)
L: 7.17 (182) W: 0.94 (24) H: 2.40 (61) HT: 2.40 (61)
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for
Pressure Contacts
height dimensions. All data subject to change without notice.
MODEL PS-1223
12 Volt 2.3 Amp. Hr.
Sealed Rechargeable
Battery
L
CAUTION
Do not make direct contact between battery terminals.
Do not discharge completely.
Recharge battery immediately after use.
Do not use other than specified battery charger.
Do not use below -10º C (15º F) or above + 40º C (105º F).
Recharge battery immediately after use.
If the temperature exceeds this upper limit,
a safety device will automatically prevent
operation of battery.
DISPOSED OF PROPERLY."
"SEALED LEAD BATTERY.
MUST BE RECYCLED OR
12 Volt 2.3 AH
MH20845
10.5
®
Positive
NONSPILLABLE
Pb
6
(mm)
HT
.5
W
13.5
Negative
6
H
.5
Features
Performance Specifi cations
N
Nominal Capacity
Approximate Weight ........................................................... 1.70 lbs. (0.77 kg)
Energy Density (20-hr. rate) ............................... 1.71 W-h/in3 (104.12 W-h/l)
Specifi c Energy (20-hr. rate) .............................. 16.24 W-h/lb (35.79 W-h/kg)
Internal Resistance (approx.) ..... This battery is protected by a bimetal circuit
Max Discharge Current (7 Min.) .................................................. 6.9 amperes
Max Short-Duration Discharge Current (10 Sec.) ....... n/a - battery is fused
Shelf Life (% of nominal capacity at 68°F (20°C))
Operating Temperature Range
Case ...................................................................................................... ABS Plastic
Power-Sonic Chargers ................................................................... PSC-12300A
ominal Voltage ........................................................................ 12 volts (6 cells)
20-hr.
10-hr.
5-hr.
1-hr.
15-min. (4.5A to 9.00 volts) .................................................................1.13 AH
1 Month ...................................................................................................... 97%
3 Months ..................................................................................................... 91%
6 Months .................................................................................................... 83%
Charge .. .......................................................... 15°F (-10°C) to 105°F (40°C)
Discharge ........................................................ 15°F (-10°C) to 105°F (40°C)
Absorbent Glass Mat (AGM) technology for superior
performance
Valve regulated, spill proof construction allows safe
operation in any position
Power/volume ratio yielding unrivaled energy density
Rugged impact resistant ABS case and cover (UL94-HB)
Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and
C.A.B. certifi ed
U.L. recognized under fi le number MH 20845
(115mA to 10.50 volts) ........................................................ 2.30 AH
(225mA to 10.50 volts) ....................................................... 2.25 AH
(390mA to 10.20 volts) ....................................................... 1.95 AH
(1.38A to 9.00 volts) ............................................................ 1.38 AH
rises above design limits the breaker is activated
breaker. If the current discharge temperature
www.power-sonic.com

Related parts for PS-1223

PS-1223 Summary of contents

Page 1

... Do not use other than specified battery charger. Do not use below -10º C (15º above + 40º C (105º F). Recharge battery immediately after use. If the temperature exceeds this upper limit, MODEL PS-1223 a safety device will automatically prevent operation of battery. ® 12 Volt 2.3 Amp. Hr. ...

Page 2

... Further Information Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 customer-service@power-sonic.com PS-1223 12 Volt 2.3 AH Discharge Characteristics 14 Ambient Temperature 20 C (68 13.0 12.0 11 ...

Related keywords