... NLP65 Series Single, dual, and triple output Total Power 75W Input Voltage 264 Vac 120 - 370 Vdc Outputs: Single, dual, triple Special Features • Universal Input • 3” x 5” footprint • Low profile fits 1U applications • EN61000-3-2 compliance option (HCC) • Overvoltage and short circuit protection • with free air convection cooling • ...
... Output Power (Watts) 75W -40 °C to +85 °C 20 CFM FORCED AIR COOLING 65W Derate to 50% load See table 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70° 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV Rev.12.12.08_102 NLP65 Series NATURAL 38W CONVECTION 32W COOLING ...
... NLP65-7612J 5.3 A 150 mV ±2.0% NLP65-7615J 3.5 A 240 mV ±2.0% NLP65-7624J 11 Conducted emissions testing were performed using the standard EN55022 set- up with a stand alone NLP65 unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to AC entry point of the system chasssis. Please contact the applications group for assistance with EMI compliance. 12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option. ...