MAP80-4003 POWER ONE, MAP80-4003 Datasheet - Page 3

Linear & Switching Power Supplies 80W 5V 14A 15V 3.5A/ -5V 1A

MAP80-4003

Manufacturer Part Number
MAP80-4003
Description
Linear & Switching Power Supplies 80W 5V 14A 15V 3.5A/ -5V 1A
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP80-4003

Product
Switching
Commercial/medical
Commercial
Output Power Rating
70 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
14 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
3.5 A
Output Voltage (channel 3)
- 5 V
Output Current (channel 3)
1 A
Mounting Style
Chassis
Dimensions
7.2 in L x 4.2 in W x 1.8 in H
Brand/series
MAP80 Series
Configuration
Open-Frame
Current, Input
2.5 A (RMS) @ 90 VAC⁄1.8 A (RMS) @ 110 VAC
Current, Leakage
500 μA (Max.)
Hold Time
20 ms (Min.) @ 115 VAC (Nom.)
Mounting Type
Panel
Operation
Switching
Output
-15 VDC @ 1 A, -5 VDC @ 1 A, +5 VDC @ 14 A, +15 VDC @ 3.5 A
Power, Output
80 W
Power, Rating
80 W (Continuous)
Primary Type
AC-DC
Special Features
TTL Compatible Power Fail Signal
Temperature, Operating
0 to 50 °C @ 100% Load
Voltage, Input
90 to 135/175 to 264 VAC
Voltage, Output
-15, -5, +5, +15 VDC
Voltage, Output 1
-5 V
Voltage, Output 2
-5 V
Voltage, Output 3
12 V
Voltage, Output 4
-12 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MCD10144 Rev. 1.0, 02-Feb-10
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Input Transient
Protection
Insulation Resistance
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Cover
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264VAC.
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C.
0°C to 70°C (After 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOTES
Add ‘C’ suffix to model number or order part number 412-59585-G separately.
For convection cooled applications, derate output power to 65 watts on all multiple
output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts.
Page 3 of 4
MAP80 AC-DC Series Data Sheet
Line to ground
At 100% load:
At 50% load:
Line to line
2600
MIN
MIN
-55
B
B
B
1
7
0
0
5
(183.0mm x 107.0mm x 52.0mm)
±0.02
NOM
NOM
7.20" x 4.20" x 2.05"
2
www.power-one.com
Approved
SIZE IMPACT
±0.03
MAX
500
MAX
10k
40k
50
70
85
95
20
6
ASL Ft.
ASL Ft.
Class
UNITS
UNITS
%/°C
%RH
G
VDC
M
µA
kV
°C
°C
°C
RMS
G

Related parts for MAP80-4003