PAS250-4AG Tamura, PAS250-4AG Datasheet

Linear & Switching Power Supplies 250W 12V 10.8A

PAS250-4AG

Manufacturer Part Number
PAS250-4AG
Description
Linear & Switching Power Supplies 250W 12V 10.8A
Manufacturer
Tamura
Datasheet

Specifications of PAS250-4AG

Product
Switching
Commercial/medical
Commercial
Output Power Rating
252 W
Input Voltage
85 VAC to 132 VAC, 180 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
21 A
Mounting Style
Chassis
Dimensions
177.8 mm L x 101.6 mm W x 38.1 mm H
Open Frame/enclosed
Open Frame
Output Type
AC/DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PAS250
250 Watts
Power Factor Correction
Single Output
Electrical Specifications
Available Voltage
Input Voltage:
Input Current:
Inrush Current:
Harmonic Distortion:
EMI Filtering:
Input Protection:
Surge Withstand:
Output Power:
Line Regulation:
Load Regulation:
PARD:
Hold-up Time:
Output Polarity:
Minimum Load:
Transient Response:
Output Rise Time:
Current Limit:
Remote Sense:
Remote On/Off:
* Consult factory for other voltages and OEM quantities.
Model
Note: Standard models are shown
PART # STRUCTURE:
Example: Part Number PAS250-7-GS= 250W Power Factor Corrected, 28V @ 9A with Field Configuable Options (Droop Share,
Single Wire Share and Square Current Limit) and Remote On/Off Invert.
CLICK HERE TO SEE THE PAS250 CODE TABLE AND AVAILABLE OPTIONS.
max
PAS250
Voltage
Codes
MODEL
-4
-5
-6
-7
-8
-9
output power
85-132/180-264 VAC, 47-63 Hz, 1 phase
<6A RMS @ 115 VAC @ full load
<35A, pk @ 265 VAC @ cold start
Meets EN61000-3-2 for Class A
Meets CISPR 11 and 22 and FCC Part 15
Internal AC line fuse; 250 VAC, 8A
Meets EN61000-4-5 Level 3
250W with 25CFM air; 130W Convection
± 0.3%
± 0.5%
<1% or 50mV;
16 ms @ full load (120 VAC)
Output is floating
0% of rated load
3% for 25% load change @ 1A/µs;
<100 ms (10% to 90%)
105-130% of rated current; Hiccup
Compensates for up to 250mV of total cable
Optional
<3A RMS @ 230 VAC @ full load
<75A, pk @ 132 VAC @ cold start
Class B (conducted)
20MHz bandwidth
50% duty cycle 50/60 Hz
drop
Outputs*
-
-
-
bold
VOLTAGE CODE
V1
X
-
-
-
OPTION CODES
Switch Mode Power Supply
Voltages
(Volts)
12.0
15.0
24.0
48.0
28.0
36.0
ABC....
Thermal Shutdown
DC OK:
Turn-on Delay:
Stability:
Isolation:
AC Power Fail:
Overvoltage Protect:
Reverse Voltage:
Efficiency:
MTBF:
H.A.L.T.
(See sheet 2)
TESTED
Standard
Standard; Open Collector
<1 second after application of AC Input
<0.1% for 8 hours
>20 MΩ @ 100 VDC between output
TTL
Factory set, 125% ±5%,
Output has reverse voltage protection;
Up to 85%
MIL-STD-HDBK 217E
after 1/2-hour warm up
terminals and chassis ground
output drops 5%; Open Collector
cycle AC to reset
Reverse current limited to 100% of output
rating
>200,000 hours @ 25°C
Highly Accelerated Life Testing
LOW
logic “0” at least 2 ms before
Continuous
Highly
Accelerated
Life
Testing
Current
(Amps)
10.5
5.5
21
17
9.0
7.2

Related parts for PAS250-4AG

PAS250-4AG Summary of contents

Page 1

... PAS250 - Example: Part Number PAS250-7-GS= 250W Power Factor Corrected, 28V @ 9A with Field Configuable Options (Droop Share, Single Wire Share and Square Current Limit) and Remote On/Off Invert. CLICK HERE TO SEE THE PAS250 CODE TABLE AND AVAILABLE OPTIONS. Switch Mode Power Supply H ...

Page 2

... Model PAS250 Options 12V@0.5A Aux./Fan Drive (A) Droop Current Share ±10% (B) Fan Assembly ( Invert (E) PF Invert (F) Field-Configurable (G) Single Wire Current Share ±5% (I) Square Current Limit (J) Molex Connector (K) Metric Mounting (M) OR-ing Diode (O) Remote On/Off (R) Remote On/Off Invert (S) Certifications NRTL Recognition to UL60950-1 CSA C22.2 No. 609501-03 ...

Related keywords