VTE24SC24 ETA-USA, VTE24SC24 Datasheet - Page 2

no-image

VTE24SC24

Manufacturer Part Number
VTE24SC24
Description
Linear & Switching Power Supplies 24V TO 24V
Manufacturer
ETA-USA
Series
VTEr
Datasheet

Specifications of VTE24SC24

Product
Switching
Output Power Rating
156 W
Input Voltage
19 VDC to 32 VDC
Number Of Outputs
1
Output Voltage (channel 1)
24 VDC
Output Current (channel 1)
6.5 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
VTD-SC / VTD-SD
Output Voltage
Output Current
Voltage Adjust Range
Ripple Noise(max) *3
Rise up time
Hold up time
Regulation
a. Line Regulation (max)
b. Load Regulation (max)
c.
d. Drift(maximum) *5
e. Dynamic Load
f. Recovery Time
Conditions:
*1 at cold start
*2 at rated input/output
*3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth
*4 at 0 to +50℃
*5 for 7hour period after 1hour warm-up at 25℃ and rated input/output
*6 when output current changed between 25% and 75% of rated output current rapidly at rated input
Environmental Specification
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Vibration
Shock
Cooling
Functions
Over current Protection
Over voltage Protection
Remote Sense
Remote On/Off
Reverse Voltage Protection
Line Conduction Noise
Weight
Dimension [mm]
Temperature Coefficient *4
Regulation (typ.) *6
Characteristic
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
ETA USA
Vin: 24,48 VDC
Output
Vin: 110 VDC
Vin:12VDC
[g](typical)
*6
Unit
mVpp
mS
mS
mV
mV
mV
mV
mS
°C
V
A
A
A
V
(Vin=24,48 100)
VTE05SCx / SD
(Vin=110 40)
(Vin=110 45)
100
150
27
30
30
25
30
40
5
+/-10% of Rated Output Voltage(at no load within input range)
0 to +50℃
85%RH(non-condensing)
-20 to +85°C
-
Primary-Secondary
Primary-Frame Ground
Secondary-Frame Ground
Primary-Secondary-Frame Ground
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for
60minutes each along X,Y,Z axes(non-operating)
294m/s2
Convection
Current Limiting with automatic recovery
Output shutdown
not available
not available
not available (Vin=110
Not specified
1.4 kg
70W × 200L × 97H
Not specified (Vin: 110 10mS(typical) at 25℃ and rated input/output)
200mS(maximum) at 25℃ and rated input/output (Vin: 110 500mS)
(Vin=24,48 120)
VTE12SCx / SD
(Vin=110 96)
Vin=110 108)
170
360
12
13
14
14
60
72
75
0.01%/℃ (Vin=110
AC1,500Vfor 1minute (Vin=110
AC1,500V for 1minute (Vin=110
(Vin=24,48 300)
(Vin=110 120)
(Vin=110 135)
VTE15SCx / SD
AC500V for 1minute
50MΩ(minimum) by DC500V insulation tester
Models
by internal bridge diode)
0.5mS
Visit us at:
200
450
email at: sales@eta-usa.com
15
10
11
11
75
90
90
www.eta-usa.com
0.03%/℃)
(Vin=110 192)
(Vin=110 216)
(Vin=24,48 480)
VTE24SCx / SD
6.5
7.0
7.0
290
120
144
135
720
24
2000)
2000)
(Vin=24,48 960)
(Vin=110 384)
(Vin=110 432)
VTE48SCx / SD
1440
3.3
3.5
4.2
530
240
288
255
48