S8VS12024B Omron, S8VS12024B Datasheet - Page 21

Linear & Switching Power Supplies 24VDC 5A SW S/RUN

S8VS12024B

Manufacturer Part Number
S8VS12024B
Description
Linear & Switching Power Supplies 24VDC 5A SW S/RUN
Manufacturer
Omron
Datasheet

Specifications of S8VS12024B

Input Voltage
100 VAC to 240 VAC
Product
Switching
Commercial/medical
Both
Output Power Rating
120 W
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
5 A
Mounting Style
DIN Rail
Dimensions
121.3 mm L x 115 mm W x 50 mm H
Open Frame/enclosed
Enclosed
Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
5A
Power Rating
120W
Length
121.3mm
Width
50mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Maintenance Forecast (S8VS-@@@24A@@)
Displays when the maintenance forecast has reached the set value.
Operation
Mode
Maintenance
forecast
monitor
Output
voltage
Output
current
Peak-hold
current
The maintenance forecast
has reached the set value.
(See note.)
Note: This indicator alternately
displays alarm (
and the maintenance
time until replacement.
Remaining time
until replacement
)
Indication and Output
When the Product is purchased, “
electrolytic capacitors deteriorate, indication changes to “
to page 22). “
display for approximately one month after the Power Supply is first
turned ON. The accumulated value will then be displayed depending
on the ambient conditions thereafter. (However, the “
may not appear, depending on the usage environment and the set
value for maintenance forecast.)
S8VS-06024A:
After the remaining time to maintenance is reduced to less than two
years, indication automatically changes to a value, which decreases
from “
increase. If the remaining time becomes less than 0.5 year, an alarm
(
S8VS-09024A@@/S8VS-12024A@,
S8VS-18024A@/S8VS-24024A@/S8VS-48024A:
If the maintenance forecast setting L (which can be set arbitrarily from
0.0 to 5.0 years in 0.5-year steps) is set to a value larger than two
years, the indication automatically changes to a value (L - 0.5) after
the remaining time to maintenance is reduced to the set years, and an
alarm (
If the setting is less than 2.0 years, the indication changes to a value
(1.5) after the remaining time becomes less than two years, and after
the remaining time becomes less than the set time, an alarm (
and the remaining time (L - 0.5) are indicated alternately.
If the alarm (
transistor (maintenance forecast output terminal (Yrs)) will turn OFF
to indicate the need for maintenance. (The transistor turns OFF when
the maintenance forecast time is reached, i.e., there will be no
continuity at the maintenance forecast output terminal.)
Note: 1. The remaining time to maintenance is based on continuous
a02
) and “
1.5
2. “
3. For details on the display, refer to Relationship between
a02
” to “
operation, not including the time when the power supply is
turned OFF.
time is accumulated to estimate the speed of deterioration
and the output will remain ON (continuity at the
maintenance forecast output terminal (Yrs)).
Indicated Values and Output of Set Values under
Maintenance Forecast Monitor Function on page 22.
ful
) and the remaining time are indicated alternately.
0.0
a02
ful
1.0
” are indicated alternately.
” will be indicated until approximately one month of
) and a numeric value are indicated alternately, a
” to “
” will be indicated for the maintenance forecast
0.5
” to “
0.0
ful
” (year) as the running hours
” will be indicated. As
In the case that the
remaining time is
reduced to smaller
than 0.5 year and an
alarm is issued.
hlf
hlf
” indication
S8VS
” (Refer
a02
)
21