POE80U-560(G)-R PHIHONG USA, POE80U-560(G)-R Datasheet - Page 3

Plug-In AC Adapters 80W 56V 1.43A Single Port Injector

POE80U-560(G)-R

Manufacturer Part Number
POE80U-560(G)-R
Description
Plug-In AC Adapters 80W 56V 1.43A Single Port Injector
Manufacturer
PHIHONG USA
Type
Power Over Ethernetr
Datasheets

Specifications of POE80U-560(G)-R

Mounting Style
POE
Input Voltage (nominal)
90 VAC to 264 VAC
Number Of Outputs
1
Output Power Rating
80 W
Output Voltage (channel 1)
56 V
Output Current (channel 1)
0.72 A
Dc Output Connector
RJ45 Connector
Ac Plug Included/required
Included
Commercial/medical
Commercial
Brand/series
POE80U Series
Configuration
Enclosed
Mounting Type
Panel
Output
56 VDC @ 1.43 A
Power, Output
80 W
Primary Type
AC-DC
Voltage, Input
90 to 264 VAC
Voltage, Output
56 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power-up Sequence:
Detection Sequence:
Fault Sequence:
Dimension Diagram Unit: mm
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal
microprocessor software. After the 2 second period, the "ON" LED will illuminate green. The DC
output voltage is now available for powering a compliant load (Phihong Proprietary detetcion).
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate.
Should the load be non-compliant then the LEDs will blink a code specific to the cause for non-
detection.
Detection Failure Codes:
1. Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink 3 times.
2. Incorrect capacitive signature – The green “ON” LED will blink 3 times.
3. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
4. Unstable current measurement – The green “ON” LED will blink 3 times
5. Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3 times
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load. Until the
correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the
output RJ45 then the LEDs will not blink but the Power Injector will continue to try to detect a valid
load.
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate.
The red “FAULT” LED will illuminate for 2 seconds and then go off as the power supply tries to re-
detect a valid load. If there is a problem detecting the load, the LED will indicate the possible fault as
per the codes in the section above.
Description of LED Functions for Gigabit Power Injector
WWW.PHIHONG.COM