1009C Murata Power Solutions Inc, 1009C Datasheet - Page 2

Transformers Pulse 1:1:1 22mH550Vus

1009C

Manufacturer Part Number
1009C
Description
Transformers Pulse 1:1:1 22mH550Vus
Manufacturer
Murata Power Solutions Inc
Type
Pulse Transformersr
Datasheet

Specifications of 1009C

Mounting Style
Through Hole
Dimensions
15.06 mm L x 15.06 mm W x 15.75 mm H
Product
Pulse Transformers
Height
15.75 mm
Length
15.06 mm
Operating Temperature Range
0 C to + 70 C
Secondary Resistance
1.3 Ohms, 1.7 Ohms
Termination Style
Through Hole
Turns Ratio
1:1:1
Width
15.06 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
TECHNICAL NOTES
ISOLATION
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isola-
tion Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time,
across a component designed to provide electrical isolation, to verify the integrity of that isolation.
All products in this series are 100% production tested at their stated isolation voltage.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in
normal operation?”
For a part holding no specific agency approvals both input and output should normally be maintained
within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure
of immunity to transient voltages and the part should never be used as an element of a safety isolation
system. The part could be expected to function correctly with several hundred volts offset applied
continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be
regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier
between these circuits and any user-accessible circuitry according to safety standard requirements.
PIN CONNECTIONS
www.murata-ps.com
A
B
C
2
4
6
2
4
6
VOLTAGE
2
6
Sec
(TOP VIEW)
S2
Sec
Pri
Pri
S1
Pri
1
3
5
1
3
5
1
5
© 2008 Murata Power Solutions, Inc.
ISO 9001 REGISTERED
MECHANICAL DIMENSIONS
All dimensions in mm (inches). Package weight: 8.0g Typ.
5.08 (0.20)
1
(0.807)
20.5
1003C
15.06 (0.593)
YYWW
10.16 (0.40)
USA:
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK:
France:
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Japan:
China:
(0.620±0.02)
Mansfield (MA), Tel: (800) 233 2765, email: sales@murata-ps.com
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Website: www.murata-ps.jp
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
15.75±0.50
5.08 (0.20)
Ø0.71±0.05
(Ø0.028±0.002)
(0.593)
15.06
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier
component can actually degrade isolation capability, to a lesser or great-
er degree depending on materials, construction and environment. While
parts can be expected to withstand several times the stated test voltage,
the isolation capability does depend on the insulative materials used.
Such materials are susceptible to chemical degradation when subject
to very high applied voltages. We therefore strongly advise against
repeated high voltage isolation testing, but if it is absolutely required,
that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for
better than functional isolation where wire enamel insulation is always
supplemented by a further insulation system of physical spacing or
barriers.
Technical enquiries - email: mk@murata-ps.com, tel:
2
(0.807)
20.5
1001C
15.06 (0.593)
YYWW
10.16 (0.40)
1000 Series
KMP_1000C_B02 Page 2 of 2
Pulse Transformers
(0.620±0.02)
15.75±0.50
+44 (0)1908 615232
10.16 (0.40)
Ø0.71±0.05
(Ø0.028±0.002)
(0.593)
15.06

Related parts for 1009C