F-108U Triad Magnetics, F-108U Datasheet

no-image

F-108U

Manufacturer Part Number
F-108U
Description
Transformers 24VCT@4A 12V@8A LUG CONNECTION
Manufacturer
Triad Magnetics
Type
Control Transformersr
Datasheets

Specifications of F-108U

Power Rating
96 VA
Primary Voltage Rating
230 V
Secondary Voltage Rating
24 V
Mounting Style
Chassis
Dimensions
71.37 mm W x 71.42 mm H
Product
Control Transformers
Height
71.42 mm
Number Of Outputs
1
Operating Temperature Range
0 C to + 130 C
Termination Style
Wire
Width
71.37 mm
Brand/series
F Series
Configuration
Bobbin
Current, Secondary
8/4 A
Frequency
50/60 Hz
Mounting Hole Centers
2.25 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Power, Rating
96 VA
Standards
UL
Temperature, Operating
+35 °C
Termination
Quick-Connect
Voltage, Primary
115/230 VAC
Voltage, Secondary
12/24 VAC
Weight
4.25 lbs.
Primary Voltages
115/230 VAC
Secondary Voltages
6/12/24 VAC
Current Rating
8A
Transformer Mounting
Chassis
Secondary Current Nom
8A
Rohs Compliant
Yes
Peak Reflow Compatible (260 C)
Yes
Input Voltage
115VAC
Leaded Process Compatible
Yes
Output Current
8A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
F-108U
Electrical Specifications (@25C)
1. Maximum Power: 96.0 VA
2. Primary:
3. Secondary:
4. Voltage Regulation: 10 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-108U transformer is part of a series of Triad Control transformers that have secondary
voltages that are commonly utilized in various electronic, electro-magnetic and electrical control
systems. These include such applications as use with relays, solenoids, small motors, speed
changers, pumps, heating elements, control valves for fluid and gases, fans, blowers, electronic
tubes, automatic assembly equipment, recording devices, elevators, door openers, low voltage
lamps, etc.
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between primary and
secondary windings as well as between the primary / secondary windings and the core.
Dimensions:
Mounting Holes: 0.203 x 0.375”
Weight: 3.240 lbs
Schematic:
Primary:
Secondary:
RoHS Compliance:
requirements of 2002/95/EC, known as the RoHS initiative.
3.812
Construction:
A
Series: 230V 50/60 Hz
Parallel: 115V 50/60 Hz
Series: 24.0VCT @ 4.0 Amps
Parallel: 12.0VCT @ 8.0 Amps
Series: 1 to 4, Jumper 3 to 2
Parallel: 1 to 3, Jumper 1 to 2 and 3 to 4
Series: 5 to 8, Jumper 7 to 6
Parallel: 5 to 7, Jumper 5 to 6 and 7 to 8
2.812
B
3.187
As of manufacturing date February 2005, all standard products meet the
C
Units: In inches
2.250
D
1
3
2
4
2.625
E
5
7
6
8
P
Chassis Mount: Control Transformer
O W E R
T
R A N S F O R M E R
1
2
5
7
B
C
D
E
6
8
3
4
A

Related parts for F-108U

F-108U Summary of contents

Page 1

... Temperature Rise: 35C TYP (45C MAX allowed) Description: The F-108U transformer is part of a series of Triad Control transformers that have secondary voltages that are commonly utilized in various electronic, electro-magnetic and electrical control systems. These include such applications as use with relays, solenoids, small motors, speed ...

Page 2

... Type Secondaries Section No. Series F-105Z 12. 1.0A A F-211Z 48. 0.25A F-106Z 12. 2.0A B F-212Z 48. 0.50A F-107Z 24. 2.0A C F-213Z 48. 1.0A D F-398U 24. 3.0A F-108U 24. 4.0A E F-214U 48. 2.0A F-399U 24. 6.0A F F-400U 48. 3.0A F-109U 24. 8.0A G F-215U 48 4. Center Tap Mounting hole sizes " Hi-pot tested at 1,500 VRMS. ...

Related keywords