ACD-6 PRO Amprobe, ACD-6 PRO Datasheet - Page 2

Clamp Multimeters & Accessories DIG CLAMP-ON METER

ACD-6 PRO

Manufacturer Part Number
ACD-6 PRO
Description
Clamp Multimeters & Accessories DIG CLAMP-ON METER
Manufacturer
Amprobe
Type
Current Clampr
Datasheets

Specifications of ACD-6 PRO

Frequency
50 Hz to 60 Hz
Maximum Ac Current
1000 A
True Rms
No
Voltage
600 V
Ranging
Auto, Manual
Display Count
4000
Features
Carrying case included
Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
600V
Current Measuring Range Ac
40A / 1000A
Resistance Measuring Range
400 Ohm To 10 MOhm
Current, Rating
400 A
Resistance
40 Megohms
Standards
CE Certified, UL Listed
Temperature, Operating
-20 to 300 °C
Voltage, Rating
600 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2730785
ACD-6 PRO 1000A Digital Clamp-on Multimeter
Electrical Specifications
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 °C ± 5 °C (73°F ± 9°F) & less than 75% R.H.
Amprobe® Test Tools
DC Voltage
NMRR :
CMRR :
Input Impedance:
Audible Continuity Tester
Open Circuit Voltage:
Audible threshold:
Resistance
Open Circuit Voltage:
AC Voltage
CMRR :
Input Impedance :
1)
Diode Tester
AC Current (Clamp-on)
1)
2)
3)
Selection by RANGE button manually, and is specified from AC 40mV (AC 60mV for True RMS model ACD-6 TRMS-PRO) and up
Add 8d to specified accuracy while reading is below 15% of range
Induced error from adjacent current carrying conductor: < 0.06A/A
Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position
errors introduced are: Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening)
Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening)
>50dB @ 50/60Hz
>120dB @ DC, 50/60Hz, Rs=1kΩ
10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
0.4VDC typical
50Hz -- 500Hz
50Hz -- 60Hz
60Hz -- 500Hz
50Hz -- 500Hz
>60dB @ DC to 60Hz, Rs=1kΩ
10MΩ, 30pF nominal
Open Circuit < 1.6 VDC
50Hz / 60Hz
0.4VDC typical
Voltage Test Current (Typical) 0.4mA
Range
400.0 mV
4.000V, 40.00V, 400.0V
600V
400.0Ω
400.0Ω
4.000kΩ, 40.00kΩ, 400.0kΩ
4.000MΩ
40.00MΩ
400.0mV
4.000V, 40.00V, 400.0V
4.000V, 40.00V, 400.0V
600V
400.0A
1000A
1)
Accuracy
1.0% + 3d
1.7% + 3d
2.0% + 4d
1.5% + 6d
between 10Ω and 120Ω.
1.5% + 6d
1.0% + 4d
1.5% + 4d
2.5% + 4d
4.0% + 5d
2.0% + 5d
2.5% + 5d
3.0% + 5d
1.5% + 5d
1.5% + 5d
www.Amprobe.com
Data Sheet