1587 Fluke, 1587 Datasheet - Page 3

Digital Multimeters INSULATION MULTMETER

1587

Manufacturer Part Number
1587
Description
Digital Multimeters INSULATION MULTMETER
Manufacturer
Fluke
Datasheet

Specifications of 1587

Accuracy
+/- 0.09 %
Resistance Range
50 M Ohms
Capacitance Range
10 mF
Equipment Type
Multimeters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2157271

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
15876020
Manufacturer:
MOLEX
Quantity:
51 871
Part Number:
1587723-1
Manufacturer:
TE
Quantity:
20 000
Part Number:
1587723-3
Manufacturer:
MOLEX
Quantity:
56 594
Part Number:
1587724-1
Manufacturer:
TE
Quantity:
20 000
Part Number:
1587724-3
Manufacturer:
TE
Quantity:
20 000
Part Number:
1587831-1
Manufacturer:
TE/泰科
Quantity:
20 000
DC and ac current measurement
1
Overload: 600 mA for 2 minutes maximum
Overload protection: 440 mA, 1000 V, FAST fuse
AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are
true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 at up
to 300 mA, decreasing linearly to crest factor < = 1.5 at 600 mA. For non-sinusoidal waveforms add + (2 %
reading + 2 % FS) typical, for a crest factor up to 3.
Ohms measurement
1
Overload protection: 1000 V rms or dc
Open circuit test voltage: < 8.0 V dc
Short circuit current: < 1.1 mA
Diode test (1587 Only)
Diode test indication: Display voltage drop: 0.6 V at 1.0 mA nominal test current
Accuracy: + (2 % + 3)
Continuity test
Continuity indication: Continuous audible tone for test resistance below 25 Ω and off above 100 Ω.
Maximum reading; 1000 Ω
Open circuit voltage: < 8.0 V
Short circuit current: 1.0 mA typical
Overload protection: 1000 V rms
Response time: > 1 m sec
Frequency measurement (1587 only)
1 kHz bandwidth
Accuracies apply from 0 to 100 % of range
AC
45 to 1000 Hz
DC
6.000 MΩ
6.000 kΩ
60.00 kΩ
600.0 kΩ
50.0 MΩ
600.0 Ω
Range
Range
9.999 kHz
99.99 kHz
99.99 Hz
999.9 Hz
Range
400 mA
400 mA
60 mA
60 mA
Resolution
Resolution
0.001 MΩ
0.001 kΩ
0.01 MΩ
0.01 mA
0.01 mA
0.01 kΩ
0.1 mA
0.1 mA
0.1 kΩ
0.1 Ω
Resolution
0.001 kHz
0.01 kHz
0.01 Hz
0.1 Hz
± (% of Rdg+Digits)
± (% of Rdg+Digits)
Accuracy 1587
Accuracy 1587
± (1.5 % + 2)
± (1.5 % + 2)
± (0.2 % + 2)
± (0.2 % + 2)
± (0.9 % + 2)
± (1.5 % + 3)
1
1
1
± (% of Rdg+Digits)
1587/1577 Insulation Multimeters
± (0.1 % + 1)
± (0.1 % + 1)
± (0.1 % + 1)
± (0.1 % + 1)
± (% of Rdg+Digits)
± (% of Rdg+Digits)
Accuracy
Accuracy 1577
Accuracy 1577
± (2.0 % + 3)
± (1.0 % + 2)
± (1.0 % + 2)
± (1.2 % + 2)
± (2 % + 2)
± (2 % + 2)
1
1
1
Burden Voltage
Fluke Corporation 3
(Typical)
2 mV/mA
2 mV/mA