38XR-A Amprobe, 38XR-A Datasheet - Page 3

Digital Multimeters PROF DMM TRUE RMS W/ OPTICAL PC INTERFACE

38XR-A

Manufacturer Part Number
38XR-A
Description
Digital Multimeters PROF DMM TRUE RMS W/ OPTICAL PC INTERFACE
Manufacturer
Amprobe
Datasheet

Specifications of 38XR-A

Accuracy
+/- 0.25 %
True Rms
Yes
Min / Max Hold
Yes
Peak Hold
Yes
Data Hold
Yes
Resistance Range
1 K Ohms to 40 M Ohms
Capacitance Range
40 nF to 400 uF
Frequency
100 Hz to 10 MHz
Equipment Type
Digital Multimeter with Optical PC Interface
Display Count
10000
Ranging
Auto
Dmm Type
Hand Held
Voltage Measuring Range Dc
1000mV To 1000V
Voltage Measuring Range Ac
1000mV To 750V
Current Measuring Range Dc
100µA To 10A
Current Measuring Range Ac
100µA To 10A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727824
Capacitance
Temperature
Frequency
Duty Cycle
4 - 20 mA DC Current Test
dBm
Continuity
Diode Test
Peak
Overload Protection
Specifications
Function
Ranges
Accuracy
Resolution
Ranges
Accuracy
Resolution
Ranges
Resolution
Ranges
Accuracy
Resolution
Frequency Range
Range
Resolution
Ranges
Accuracy
Resolution
Audible Indication
Test Current
Open Circuit Volts
AC Volts Accuracy
AC Current
AC/DC Voltage
AC/DC Current
(23 °C ± 5 °C, <75 % R.H. non-condensing), cont.
Range
40 nF, 400 nF, 4 μF, 40 μF, 400 μF
40 nF, 400 μF ranges:
400 nF to 40 μF ranges:
0.01 nF
-20 °C to 1300 °C, -4 °F to 2372 °F
-20 °C to 10 °C:
10 °C to 200 °C:
200 °C to 1300 °C:
-4 °F to 50 °F:
50 °F to 400 °F:
400 °F to 2372 °F:
1 °C, 1 °F
100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz ± (0.1% rdg + 5 dgts)
0.01 Hz
0 to 90 %
5 V logic:
0.01 %
0 % to 10 %: 40 Hz to 990 Hz
10 % to 90 %: 40 Hz to 20 kHz
0 – 100 %
0.01 %
-13 dBm to + 50 dBm
45 Hz to 5 kHz: ± (0.7 dB + 8 dgts)
5 kHz to 10 kHz: ± (2.5 dB + 8 dgts)
0.01 dBm
< 40 W
0.5 mA (approximate)
3.0 V DC typical
100 V, 750 V ranges:
1000 mV, 10 V ranges: unspecified
1000 V DC or 750 V AC RMS
μA/mA input: F0.5 A /1000 V fast-blow ceramic 6.3 x 32 mm
10A input: F10 A /1000V fast-blow ceramic 10 x 38 mm
± (3.0 % rdg + 10 dgts)
± (3.0 % rdg + 5 dgts)
± (2.0 % rdg + 4 °C )
± (1.0 % rdg + 3 °C )
± (2.0 % rdg + 2 °C )
± (2.0 % rdg + 8 °F)
± (1.0 % rdg + 6 °F)
± (2.0 % rdg + 4 °F)
± (2.0% rdg + 10 dgts)
± (0.5 % + 5 dgts)
± (3.0 + 200 dgts)
± (3.0 + 200 dgts)
www.Amprobe.com
Accuracy