PM55A Amprobe, PM55A Datasheet - Page 3

Digital Multimeters AUTOMATIC PRECISION POCKET DMM

PM55A

Manufacturer Part Number
PM55A
Description
Digital Multimeters AUTOMATIC PRECISION POCKET DMM
Manufacturer
Amprobe
Type
DMMr
Datasheet

Specifications of PM55A

True Rms
No
Min / Max Hold
No
Peak Hold
No
Data Hold
No
Resistance Range
600 Ohms to 6 M Ohms
Capacitance Range
1000 nF to 2000 uF
Frequency
10 Hz to 30 KHz/10 Hz to 999.9 Hz
Equipment Type
Compact Precision Digital Multimeter
Display Count
6000
Ranging
Auto
Dmm Type
Handheld
Voltage Measuring Range Dc
6V To 600V
Voltage Measuring Range Ac
6V To 600V
Current Measuring Range Dc
400µA To 2000µA
Current Measuring Range Ac
400µA To 2000µA
Battery Type
3V standard button
Current, Range
400.0 uA for both AC and DC
Dimensions
4.4 × 2.1 × 0.4 In.
Display Type
LCD
Frequency Range
10.00 Hz - 30.00 kHz Sine-RMS
Resistance, Range
600.0 Ohm, 6.000 kOhm, 60.00 kOhm, 600.0 kOhm, 6.000 MOhm
Temperature, Operating
0 °C to 40 °C
Voltage, Range, Ac
6.000 V, 60.00 V, 600 V
Voltage, Range, Dc
6.000 V, 60.00 V, 600 V
Weight
3 Oz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727721
PM55A Digital Multimeter
Specifications
DC μA Current
AC μA Current
Function
Capacitance
Resistance
Range Accuracy
Open circuit voltage 0.4 V DC typical
Frequency
VolTect™
Detection frequency 50/60 Hz
Diode Test
1
2
3
1
2
1
2
Typical voltage Bar graph indication
Indication Bar graph segments & audible beep tones proportional to field strength
Detection antenna Top left corner of the meter
Audible Continuity Tester (600 W range)
Open circuit voltage 0.4 V DC typical
Audible threshold 50 W to 300 W
Diode test current 0.48 mA
Open circuit voltage < 1.6 V DC
Accuracy below 50 nF is not specified 4Specified with battery voltage above 2.8 V (half full battery).
AutoTect™ is for 6.000 kW ~ 6.000 MW ranges
Sensitivity (Sine-rms): Hz in Auto-V ( position:> 3 V
Accuracies with film capacitor or better Accuracy decreases gradually to 12% at low battery warning
Updates > 1 minute on large values voltage of approx. 2.4 V.
Add 40 dgt to specified accuracy while reading is below 20 % of range
Line-level Hz in V position: @6.000 V AC range: > 3 V; @60.00 V AC range: > 6 V; @600.0 V AC range: > 60 V
15 V to 55 V
30 V to 85 V
55 V to 145 V
85 V to 190 V
above 120 V
100.0 nF, 1000 nF, 10.0 μF,
100.0 μF, 2000 μF
600.0 W
6.000 kW
60.00 kW, 600.0 kW
6.000 MW
10.00 Hz - 30.00 kHz
10.00 Hz - 999.9 Hz
– –
– – –
– – – – –
Range
– – – –
Range
400.0 μA
2000 μA
Range
400.0 μA
2000 μA
1 3
1, 2
Accuracy
± (1.5 %+3 dgt)
± (1.2 %+3 dgt)
Accuracy
± (2.0 %+3 dgt)
± (1.5 %+3 dgt)
± (3.5 %+6 dgt)
± (2.0%+6 dgt)
± (1.2%+6 dgt)
± (1.0%+4 dgt)
± (2.0%+4 dgt)
± (0.5 %+4 dgt) < 2 0 V Sine-rms
± (0.5 %+4 dgt) < 600 V Sine-rms
Accuracy
Burden voltage
6 mV/μA
6 mV/μA
Burden voltage
6 mV/μA
6 mV/μA
2
2
2
www.Amprobe.com
Data Sheet