DLRO10X Megger, DLRO10X Datasheet - Page 3

Digital Multimeters Enhanced 10 Amp DLRO

DLRO10X

Manufacturer Part Number
DLRO10X
Description
Digital Multimeters Enhanced 10 Amp DLRO
Manufacturer
Megger
Datasheet

Specifications of DLRO10X

Accuracy
+/- 10 %
Resistance Range
100 m Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Measurement:
Display:
Test Method:
Test Current:
Maximum Lead Resistance:
Voltmeter input impedance:
Hum rejection:
Data:
Battery:
Charging Rate:
Temperature:
Humidity (max):
Altitude (max):
Safety:
EMC:
Dimensions:
Weight:
Full Scale
1.9999 mΩ
19.999 mΩ
199.99 mΩ
1.9999 Ω
19.999 Ω
199.99 Ω
1999.9 Ω
Range and Safety:
Slow charging:
Measurement:
Fast charging:
Co-efficient:
Memo Field
Calibration:
Resolution
0.1 µΩ
1 µΩ
10 µΩ
100 µΩ
1 mΩ
10 mΩ
100 mΩ
Operation:
Recharge:
Accuracy:
Standard:
Capacity:
Stability:
Transfer:
Control:
Storage:
Storage:
Speed:
Mode:
Life:
Accuracy
±0.2% ±0.2µΩ
±0.2% ±2 µΩ
±0.2% ±20 µΩ
±0.2% ±0.2 mΩ
±0.2% ±2 mΩ
±0.2% ±20 mΩ
±0.2% ±0.2 Ω
DLRO 10
Manual, Auto, Continuous,
High Power
Fully Automatic
<3s for forward & reverse current and to display average
41/2 digit seven segment LED
LED indication
Single cycle reversing d.c. ratiometric measurement -average result display.
±10%
<10 ppm per second
100 mΩ total for 10A operation irrespective of battery condition.
> 200 kΩ
Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning
will show if hum or noise exceeds this level.
7 Ah NiMH rechargeable
Typically 1000 x 10 A tests before recharge
Via External 90V - 260V 50/60 Hz charger or from 12 to 15V d.c. supply
2.5 hours to 90% capacity, 4 hrs for full charge
+5ºC to +45ºC (41ºF to 113ºF) at full specification
-10ºC to +50ºC (14ºF to 122ºF) at reduced accuracy
-30ºC to +70ºC (-22ºF to 158ºF)20ºC (68ºF)
<0.01% per ºC over range 5ºC to 40ºC
<0.01% per ºC from 5ºC to 40ºC (<0.006% per oF from 41ºF to 104ºF)
0ºC to +45ºC (32ºF to 113ºF)
+10ºC to +45ºC (50ºF to 113ºF)
90% RH @ 40ºC (104ºF) non-condensing
2000m (6500 ft) to full safety specifications
In accordance with EN61010-1 600V Category III
The instrument meets EN50081-1 and EN50082-1 (1992)
220 x 100 x 237 mm (8.6 x 4 x 9.5 in)
2.6 kg (5 3/4 lb.) including battery module.
Resistive
20 mV
20 mV
20 mV
20 mV
20 mV
20 mV
200 mV
Full Scale Volts
Inductive
n/a
20 mV
200 mV
200 mV
200 mV
200 mV
200 mV
Manual, Auto, Continuous,
High Power, Unidirectional
Fully Automatic/Manual
Large backlit LCD
Real Time or from storage via RS232
700 tests
Up to 256 characters per test via integral
alphanumeric keypad
Resistive
10 A
1 A
100 mA
10 mA
1 mA
100 µA
100 µA
DLRO 10 AND DLRO 10X
Test Current
Inductive
n/a
1 A
1 A
100 mA
10 mA
1 mA
100 µA
DLRO 10X
Digital Microhmmeter